Minimum floor area
• The appliance shall be installed, operated and stored in a room with a floor area larger than the minimum area.
• Use the graph of table to determine the minimum area.
Amin (m
2
)
600
500
400
300
200
100
0
0
1.224
• m : Total refrigerant amount in the system
• Total refrigerant amount : factory refrigerant charge + additional refrigerant amount
• Amin : minimum area for installation
2
3
4
- 18 -
Part 1 General Information
5
6
7
Copyright © 2019 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
Floor standing
Wall mounted
Ceiling mounted
m (kg)