This manual corresponds to the following references: JTSE-1A (100V/120V) JTSE-2A (230V) Packing List The following items are included: JTU Hot Air Control Unit ......1 unit JTS Stand ............1 unit Ref. JT-SE JTT Heater Hose Set .........1 unit Power Cable ..........1 unit Ref.
Page 3
para manuales - color gris 200 mm 130 mm 130 mm 100 mm Nozzle ......1 unit Nozzle ......1 unit Nozzle ......1 unit Ref. JN2015 Ref. JN2012 Ref. JN2020 (Ø 4mm / 0.157in) (Ø 6mm / 0.236in) (Ø 8mm / 0.315in) 80 mm 60 mm 50 mm...
Features and Connections USB-A Connector Heating Element Thermocouple Type K Activates the Suction Pump Hot Air Button (On / Off) JTT Heater Hose Set Ref. JT-T1A (100V/120V) JT-T2A (230V) Suction Tube Ref. 0932330 For tripods and extractors Extractor 64 (20x26mm) Ref.
para manuales - color gris 200 mm JT / TE Work Screen 130 mm 130 mm JT/TE offers an intuitive user interface which provides quick access to station parameters. Default PIN: 0105 100 mm Status Bar 17:14 Time to 80 mm Stop 4m 38s Instant Power...
Advanced Functionalities To work with profiles it is essential to use RWB / RWS / RWT rework arms. The Rework Arms supports the Hot Air Heater maintaining the distance and position to the component. Profiles In this mode you can set up or edit as many as 25 profiles of temperature and air flow. Profile 3m 18s Name...
Insert a USB flash drive into the USB-A connector to save your soldering process in csv format. Files Station Update Download the JBC Update File from www.jbctools.com/software.html Insert the USB flash drive with the file down- loadedto the station. Update...
Adjustable Stand Adjust the tool holder angle to suit your work position. Operation Modes 1. From the Tool Settings Menu, select the mode to activate the tool depending on the task. Tool button Pedal (not included) Press Press Press the Pedal (Ref. P-305) to blow hot air Press the start/stop button to blow hot air.
para manuales - color gris 200 mm Operation 130 mm 130 mm 1. Placing 2. Heating 3. Extracting 100 mm 80 mm 60 mm Position the extractor with the Heat the component. The component lifts off appropriate suction cup and automatically when the press the suction button.
Page 10
Pick & Place (not included) This tool helps you place and remove SMDs of any size easily thanks to the suction pump. Pick & Place Bent Needles Set Straight Needles Set Ref. T260-A Ref. 0861660 Ref. 0901546 Operation Choose the needle and the suction cup that best fits the component and start as follows: Press the button to start/stop the suction Suction Cup Set...
Page 11
para manuales - color gris 200 mm Accessories 130 mm 130 mm Protectors No.* Ref. AxB (mm) AxB (in) No.* Ref. AxB (mm) AxB (in) 4,3 x 3 0.16 x 0.12 12 x 23 0.47 x 0.9 P3353 P1249 100 mm P3786 5,2 x 5,2 0.20 x 0.20...
Page 12
Using the Thermocouple Type K Connect a TC type K (PH218) to the station and use it as a protection or regulation sensor. You can define its use mode by means of the “Ext TC mode” option in the “Tool” menu. You can choose from two work modes: Regulation: the station regulates the air Protection: the station cuts the air supply off...
Page 13
para manuales - color gris 200 mm Quick Nozzle Changer 130 mm 130 mm Changing nozzles quickly and safely. 100 mm Turn the tool off and handle with care. The heating element and the nozzle are still hot. 80 mm 60 mm Compatible Nozzles JTT works with JT nozzles.
Replacing the Heating Element Only perform this operation when the element is cold and the unit is disconnected from the mains. 1. Loosen the screw. 2. Pull the heating element out of the handle. 3. Connect the new heating element, ensuring it is pushed all the way in. 4.
Employer uniquement avec Employer uniquement avec un fusible de 250V un fusible de 250V Fuse holder - Replace any defective or damaged pieces. Use original JBC spare parts only. - Repairs should only be performed by a JBC authorized technical service.
Page 16
Safety It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. - Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. - The power cord must be plugged into approved bases. Be sure that it is properly grounded before use.
Page 17
para manuales - color gris 200 mm Notes 130 mm 130 mm 100 mm 80 mm 60 mm 50 mm 40 mm...
para manuales - color gris 200 mm Specifications 130 mm 130 mm Hot Air Station 100 mm Ref. JTSE-1A 100V - 120V 50/60Hz. Input fuse: 8A. Rated current: 7A Ref. JTSE-2A 230V 50/60Hz. Input fuse: 4A. Rated current: 3A - Temperature selection: Room temp.
Page 20
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased. Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase. This product should not be thrown in the garbage.
Need help?
Do you have a question about the JT JTSE-1A and is the answer not in the manual?