3.1.1 Natural Gas (The appliance test
point is located at the regulator)
The supplied regulator must be fitted to the ap-
pliance inlet connection. Gas pressure must be
adjusted to 1.0 kPa when approximately 50%
of the burners are on high flame.
1. Test Point location
2. Gas inlet pipe
3. Elbow
4. Regulator
3.1.2 Universal LPG (The appliance test
point is located at the injector)
Gas pressure must be checked to confirm the appli-
ance operating pressure is 2.75 kPa, the appliance
test point is the Rapid burner injector as shown.
1. Disconnect power.
2. Light the auxiliary burner and set to high flame.
Ensure all other burners are off.
3. Zero manometer, then apply flexible tubing
to seal over the Rapid burner injector, hold
securely in place and check the gas pressure by
pressing in the corresponding burner control
knob in, then turning to high flame position.
4. If the pressure is 2.75 kPa, reassemble the
burner and perform the final checks as per this
instruction manual.
5. If the pressure is not 2.75 kPa, disconnect
the appliance and check/adjust/replace the
LPG cylinder regulator(s) as appropriate in
accordance with AS/NZS 5601.
14 / EN
Patent 2015101170. For enquires contact Gas
Approval Consulting Pty Ltd BEKO licence 034 for
AGA 8624 G.
3.1.3 Requirement 1 Overhead
clearances—(Measurement A)
Range hoods and exhaust fans shall be in-
stalled in accordance with the manufacturer's
relevant instructions. However, in no case shall
the clearance between the highest part of
the cooktop of the gas cooking appliance and
a range hood be more than 600 mm or, for an
overhead exhaust fan, 750 mm.