Overview Of Units - Mitsubishi Electric PUMY-P112VKM4 Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P112VKM4:
Table of Contents

Advertisement

2

OVERVIEW OF UNITS

2-1. SYSTEM CONSTRUCTION
Outdoor unit
Capacity
Applicable
Number of units
indoor unit
Total system capacity range
Branching pipe
components
Model
Cassette Ceiling
4-way flow
2 by 2
*7
PLFY-P
PLFY-P PLFY-EP
Capacity
10
15VFM-E
15
15VCM-E
20VFM-E
20VBM-E
20
20VCM-E
20VEM-E
25VFM-E
25VBM-E
25
25VCM-E
25VEM-E
32VFM-E
32VBM-E
32
32VCM-E
32VEM-E
40VFM-E
40VBM-E
40
40VCM-E
40VEM-E
50VBM-E
50VFM-E
50
50VEM-E 50VLMD-E
50VEM-E
63VBM-E
63
63VEM-E 63VLMD-E
63VEM-E
71
80VBM-E
80
80VEM-E 80VLMD-E
80VEM-E
100VBM-E
100
100VEM-E
125VBM-E
125
125VEM-E
140
Note: Only for R1 models: PEFY-P·VMA(L)-E3, PKFY-P·VLM, PFFY-P·VCM
Name
Model number
Remote
controller
Functions
. When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110% (100%
*1
in case of heating below −5:.)
. When connecting PWFY series (Note that the connection is not allowed inside EU countries.)
*2
• Only 1 PWFY-P100VM-E-AU can be connected. PWFY-P200VM-E-AU and PWFY-P100VM-E-BU cannot be connected.
• The PWFY unit cannot be the only unit connected to an outdoor unit. Select an indoor unit so that the total rated capacity of the indoor
units, excluding the PWFY unit, is 50 to 100% of the outdoor unit capacity.
*3
. PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*4
. When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
. Authorized connectable indoor units are as follows;
*5
PUMY-P112: PEFY-P25VMA3-E × 2 + PEFY-P32VMA3-E × 2
PUMY-P125: PEFY-P32VMA3-E × 4
PUMY-P140: PEFY-P32VMA3-E × 3 + PEFY-P40VMA3-E × 1
*6
. Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*7
. For the PLFY-EP・VEM-E, up to 2 units can be connected. Other indoor units excluding the PEFY-P・VMA3-E and PEFY-P・VMH-EF can be
connected within the total rated capacity and maximum number of connected units.
OCH673C
4HP
PUMY-P112VKM4(-BS)
PUMY-P112VKM4R1(-BS)
PUMY-P112YKM(E)4(-BS)
PUMY-P112YKM(E)4R1(-BS)
1 to 9 unit
CMY-Y62-G-E
Branch header
(2 branches)
Ceiling
Wall
Concealed
Mounted
2-way flow 1-way flow
PLFY-P PMFY-P
PEFY-P
PKFY-P
10VLM-E
15VMS1(L)-E 15VBM-E
15VLM-E
20VMS1(L)-E
20VMA(L)-E
20VBM-E
20VLMD-E 20VBM-E
20VLM-E
20VMA(L)-E3
20VMR-E-L/R
25VMS1(L)-E
25VMA(L)-E
25VBM-E
25VLMD-E 25VBM-E
25VMA(L)-E3
25VLM-E
25VMR-E-L/R
*5
25VMA3-E
32VMS1(L)-E
32VMA(L)-E
32VHM-E
32VLMD-E 32VBM-E
32VMA(L)-E3
32VLM-E
32VMR-E-L/R
*5
32VMA3-E
40VMS1(L)-E
40VMA(L)-E
40VHM-E
40VLMD-E 40VBM-E
40VMA(L)-E3
40VLM-E
40VMH-E
*5
40VMA3-E
50VMS1(L)-E
50VMA(L)-E
50VHM-E
50VLM-E
50VMA(L)-E3
50VMH-E
63VMS1(L)-E
63VMA(L)-E
63VKM-E
63VMA(L)-E3
63VMH-E
71VMA(L)-E
71VMA(L)-E3
71VMH-E
80VMA(L)-E
80VMA(L)-E3
80VMH-E
100VMA(L)-E
100VLMD-E
100VMA(L)-E3
100VKM-E 100VKM-E
100VMH-E
125VMA(L)-E
125VLMD-E
125VMA(L)-E3
125VMH-E
140VMA(L)-E
140VMA(L)-E3
140VMH-E
M-NET remote controller
PAR-F27MEA-E,
PAR-U02MEDA
• A handy remote controller for use in
conjunction with the Melans centralized
management system.
• Addresses must be set.
5HP
PUMY-P125VKM4(-BS)
PUMY-P125VKM4R1(-BS)
PUMY-P125YKM(E)4(-BS)
PUMY-P125YKM(E)4R1(-BS)
Type 10 to Type 140
1 to 10 unit
50 to 130% of outdoor unit capacity
CMY-Y64-G-E
Branch header
(4 branches)
Ceiling
Floor standing
Suspended
Exposed
Concealed
PCFY-P
PFFY-P
PFFY-P
20VLRM-E
20VLEM-E
20VLRMM-E
20VKM-E
20VCM-E
25VLRM-E
25VLEM-E
25VLRMM-E
25VKM-E
25VCM-E
32VLRM-E
32VLEM-E
32VLRMM-E
32VKM-E
32VCM-E
40VLRM-E
40VLEM-E
40VKM-E
40VLRMM-E
40VKM-E
40VCM-E
50VLRM-E
50VLEM-E
50VLRMM-E
50VCM-E
63VLRM-E
63VKM-E
63VLEM-E
63VLRMM-E
63VCM-E
125VKM-E
MA remote controller
PAR-21MAA, PAR-31/32MAA
PAR-W21MAA(when using PWFY)
• Addresses setting is not
necessary.
5
6HP
PUMY-P140VKM4(-BS)
PUMY-P140VKM4R1(-BS)
PUMY-P140YKM(E)4(-BS)
PUMY-P140YKM(E)4R1(-BS)
1 to 12 unit
*1 *2
CMY-Y68-G-E
Branch header
(8 branches)
Ceiling
Air to
Lossnay
concealed
Water
*2
*3
unit
Fresh air
*6
PEFY-P
GUF
PWFY-P
50RD(H)4
80VMH-E-F
100VM-E1-AU
100RD(H)4
100VM-E2-AU
140VMH-E-F
CONNECTION KIT
PAC-LV11M-J
*4
M series indoor unit
MSZ-SF Series
MSZ-EF Series
MSZ-FH Series
MFZ-KJ Series
MSZ-LN·VG Series
MSZ-AP·VG Series
MSZ-AP·VF Series
M series remote
controller

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents