Connectors

I/O Connector
6-pin configurable terminal block for:
4-pin terminal block for:
• Auxiliary power (DC output)
• Digital Input
• Digital Output
• 0 V DC (-)
Note
The I/O connector is connected to the housing (fan/heater) on delivery. In the case of a fan or heater error, an input signal
will be triggered in the camera. Set up an action rule in the camera to configure which action the signal shall trigger. For
information about events and action rules, see Events on page 42.
The I/O connector is connected to the housing (fan/heater) on delivery. In the case of a fan or heater error, an input signal
will be triggered in the camera. Set up an action rule in the camera to configure which action the signal shall trigger. For
information about events and action rules, see the User Manual available on www.axis.com
Function
Pin
1
0 V DC (-)
2
DC output
Configurable
3–6
(Input or Output)
Function
Pin
1
0 V DC (-)
2
DC output
3–4
Configurable
(Input or Output)
Function
Pin
1
0 V DC (-)
2
DC output
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
79
Specifications
0 V DC
3.3 V DC
Max load = 250 mA
0 to max 40 V DC
0 to max 40 V DC, open drain,
100 mA
Specifications
0 V DC
3.3 V DC
Max load = 250 mA
0 to max 40 V DC
0 to max 40 V DC, open drain,
100 mA
Specifications
0 V DC
3.3 V DC
Max load = 50 mA