Advertisement

Quick Links

KA01292D/06/EN/02.19
71424710
2019-02-01
Products
Brief Operating Instructions
Flowmeter
Proline 500 – digital
FOUNDATION Fieldbus transmitter
with electromagnetic sensor
These instructions are Brief Operating Instructions; they are
not a substitute for the Operating Instructions pertaining to
the device.
Brief Operating Instructions part 2 of 2: Transmitter
Contain information about the transmitter.
Brief Operating Instructions part 1 of 2: Sensor →  3
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FOUNDATION Proline 500 digital and is the answer not in the manual?

Questions and answers

Summary of Contents for Endress+Hauser FOUNDATION Proline 500 digital

  • Page 1 Products Solutions Services KA01292D/06/EN/02.19 71424710 2019-02-01 Brief Operating Instructions Flowmeter Proline 500 – digital FOUNDATION Fieldbus transmitter with electromagnetic sensor These instructions are Brief Operating Instructions; they are not a substitute for the Operating Instructions pertaining to the device. Brief Operating Instructions part 2 of 2: Transmitter Contain information about the transmitter.
  • Page 2 Flowmeter Proline 500 – digital Order code: XXXXX-XXXXXX Ser. no.: XXXXXXXXXXXX Ext. ord. cd.: XXX.XXXX.XX Serial number www.endress.com/deviceviewer Endress+Hauser Operations App A0023555 Endress+Hauser...
  • Page 3 These Brief Operating Instructions are the Brief Operating Instructions part 2: Transmitter. The "Brief Operating Instructions part 1: Sensor" are available via: • Internet: www.endress.com/deviceviewer • Smart phone/tablet: Endress+Hauser Operations App Detailed information about the device can be found in the Operating Instructions and the other documentation: • Internet: www.endress.com/deviceviewer •...
  • Page 4: Table Of Contents

    Diagnostic information ............39 Endress+Hauser...
  • Page 5: About This Document

    Result of a step Visual inspection 1.1.3 Electrical symbols Symbol Meaning Symbol Meaning Direct current Alternating current Direct current and alternating current Ground connection A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system. Endress+Hauser...
  • Page 6 Allen key Open-ended wrench 1.1.6 Symbols in graphics Symbol Meaning Symbol Meaning 1, 2, 3,... Item numbers … Series of steps A, B, C, ... Views A-A, B-B, C-C, ... Sections Hazardous area Safe area (non-hazardous area) Flow direction Endress+Hauser...
  • Page 7: Basic Safety Instructions

    Danger of breakage due to corrosive or abrasive fluids and ambient conditions! ‣ Verify the compatibility of the process fluid with the sensor material. ‣ Ensure the resistance of all fluid-wetted materials in the process. ‣ Keep within the specified pressure and temperature range. Endress+Hauser...
  • Page 8: Workplace Safety

    Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 9: Device-Specific It Security

    The device offers a range of specific functions to support protective measures on the operator' s side. These functions can be configured by the user and guarantee greater in-operation safety if used correctly. For detailed information on device-specific IT security, see the Operating Instructions for the device. Endress+Hauser...
  • Page 10: Product Description

    The transmitter and sensor are mounted in physically separate locations. They are interconnected by a connecting cable. Transmitter Connecting cable: cable, separate, standard Sensor connection housing with integrated ISEM (intelligent sensor electronics module) For detailed information on the product description, see the Operating Instructions for the device Endress+Hauser...
  • Page 11: Installation

    Excessive tightening torque applied to the fixing screws! Risk of damaging the plastic transmitter. ‣ Tighten the fixing screws as per the tightening torque: 2 Nm (1.5 lbf ft) ø 20…70 TX 25 ø ( 0.79…2.75) SW 10 A0029051  1 Engineering unit mm (in) Endress+Hauser...
  • Page 12: Wall Mounting

    Mounting the transmitter housing: – Post mounting – Wall mounting Is the device undamaged (visual inspection)?  Post mounting:  Have the fixing screws been tightened with the correct tightening torque? Wall mounting:  Are the securing screws tightened securely? Endress+Hauser...
  • Page 13: Electrical Connection

    Cable diameter • Cable glands supplied: M20 × 1.5 with cable ⌀ 6 to 12 mm (0.24 to 0.47 in) • Spring-loaded terminals: Suitable for strands and strands with ferrules. Conductor cross-section 0.2 to 2.5 mm (24 to 12 AWG). Endress+Hauser...
  • Page 14 Current output 0/4 to 20 mA Standard installation cable is sufficient. Pulse/frequency/switch output Standard installation cable is sufficient. Relay output Standard installation cable is sufficient. Current input 0/4 to 20 mA Standard installation cable is sufficient. Status input Standard installation cable is sufficient. Endress+Hauser...
  • Page 15 The sensor and transmitter, which are mounted in separate locations, are interconnected by a connecting cable. The cable is connected via the sensor connection housing and the transmitter housing. Terminal assignment and connection of the connecting cable →  19. Endress+Hauser...
  • Page 16 Remove dummy plug if present. If the measuring device is supplied without cable glands: Provide suitable cable gland for corresponding connecting cable. If the measuring device is supplied with cable glands: Observe requirements for connecting cables →  13. Endress+Hauser...
  • Page 17 70 (2.76) 8 (0.3) 10 (0.4) 40(1.57) 8 (0.31) A0029546 A0029442 Engineering unit mm (in) A = Terminate the cable B = Fit ferrules on cables with fine-wire cores (stranded cables) 1 = Red ferrules,  1.0 mm (0.04 in) Endress+Hauser...
  • Page 18 A = Terminate the cable B = Fit ferrules on cables with fine-wire cores (stranded cables) 1 = Red ferrules,  1.0 mm (0.04 in) 2 = White ferrules,  0.5 mm (0.02 in) * = Stripping only for reinforced cables Endress+Hauser...
  • Page 19: Connecting The Measuring Device

    Cable entry for cable on transmitter housing Protective earth (PE) Connecting cable ISEM communication Grounding via ground connection; on device plug versions grounding is through the plug itself Cable entry for cable or connection of device plug on sensor connection housing Protective earth (PE) Endress+Hauser...
  • Page 20 Connection via connectors with order code for "Sensor connection Available for sensor housing" Option C "Ultra-compact hygienic, stainless" →  23 Promag H Connecting the connecting cable to the transmitter The cable is connected to the transmitter via terminals →  24. Endress+Hauser...
  • Page 21 Housing degree of protection voided due to insufficient sealing of the housing. ‣ Screw in the thread on the cover without using any lubricant. The thread on the cover is coated with a dry lubricant. Screw on the housing cover. Tighten the securing clamp of the housing cover. Endress+Hauser...
  • Page 22 Connect the cable in accordance with the connecting cable terminal assignment →  19. Firmly tighten the cable glands.  This concludes the process for connecting the connecting cable. Close the housing cover. Tighten the securing screw of the housing cover. Endress+Hauser...
  • Page 23 Flowmeter Proline 500 – digital Electrical connection Connecting the sensor connection housing via the connector A0029615 Connect the protective ground. Connect the connector. Endress+Hauser...
  • Page 24  This concludes the process for connecting the connecting cable. Close the housing cover. 10. Tighten the securing screw of the housing cover. 11. After connecting the connecting cable: Connect the signal cable and the supply voltage cable →  25. Endress+Hauser...
  • Page 25 Terminal connection for signal transmission, input/output; optional: connection for external WLAN antenna Protective earth (PE) TX 20 TX 20 10 (0.4) 22 mm 24 mm A0029597 Loosen the 4 fixing screws on the housing cover. Open the housing cover. Fold open the terminal cover. Endress+Hauser...
  • Page 26 Excessive tightening torque applied to the fixing screws! Risk of damaging the plastic transmitter. ‣ Tighten the fixing screws as per the tightening torque: 2 Nm (1.5 lbf ft) 11. Tighten the 4 fixing screws on the housing cover. Endress+Hauser...
  • Page 27: Ensuring Potential Equalization

    • Grounding rings can be ordered separately as an accessory from Endress+Hauser . When ordering make sure that the grounding rings are compatible with the material used for the...
  • Page 28 Potential equalization via additional grounding ring A0028971 Hexagonal-headed bolts of process connection O-ring seals Plastic disk (spacer) or grounding ring Sensor Potential equalization via grounding electrodes on process connection A0028972 Hexagonal-headed bolts of process connection Integrated grounding electrodes O-ring seal Sensor Endress+Hauser...
  • Page 29 If DN ≥ 350 (14"): Mount the ground cable directly on the metal transport bracket. Observe screw tightening torques: see the Sensor Brief Operating Instructions. Connect the connection housing of the transmitter or sensor to ground potential by means of the ground terminal provided for the purpose. Endress+Hauser...
  • Page 30 Prerequisite: The sensor is installed in the pipe in a way that provides electrical insulation. Connect the two flanges of the pipe to one another via a ground cable. Guide the shield of the signal lines through a capacitor. Endress+Hauser...
  • Page 31: Ensuring The Degree Of Protection

    Do the cables used meet the requirements?  Do the cables have adequate strain relief?  Are all the cable glands installed, firmly tightened and leak-tight? Cable run with "water trap" →  31?  Is the potential equalization established correctly ?  Endress+Hauser...
  • Page 32: Operation Options

    Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370 Field Xpert SMT70 Mobile handheld terminal Control system (e.g. PLC) Endress+Hauser...
  • Page 33: Structure And Function Of The Operating Menu

    The individual parts of the operating menu are assigned to certain user roles (operator, maintenance etc.). Each user role contains typical tasks within the device lifecycle. For detailed information on the operating philosophy, see the Operating Instructions for the device. Endress+Hauser...
  • Page 34: Access To The Operating Menu Via The Local Display

    2.6 Explanatory symbols for measured value 2: measured value type, measuring channel number Navigation view: picklist of a parameter 3.1 Navigation path and status area 3.2 Display area for navigation:  designates the current parameter value Editing view: text editor with input mask Editing view: numeric editor with input mask Endress+Hauser...
  • Page 35 Moves the input position one position to the left. Switches to the selection of the correction tools. Deletes one character immediately to the left of the input position. Toggle • Between upper-case and lower-case letters • For entering numbers • For entering special characters Endress+Hauser...
  • Page 36 • Pressing the key for 2 s in the case of a parameter: Returns you to the operational display ("home position"). With a wizard: Exits the wizard and takes you to the next higher level. With a text and numeric editor: Closes the editor view without applying any changes. Endress+Hauser...
  • Page 37: Access To The Operating Menu Via The Operating Tool

    For detailed information on system integration, see the Operating Instructions for the device. • Overview of device description files: – Current version data for the device – Operating tools • Cyclic data transmission – Block model – Description of the modules – Execution times – Methods Endress+Hauser...
  • Page 38: Commissioning

    Main menu 0104-1 Display language English Operation Setup Display language 0104-1 English à Deutsch Español Français Display language 0104-1 à English Deutsch Español Français Hauptmenü 0104-1 Sprache Deutsch Betrieb Setup A0029420  7 Taking the example of the local display Endress+Hauser...
  • Page 39: Configuring The Measuring Device

    For detailed information on protecting the settings against unauthorized access, see the Operating Instructions for the device. Diagnostic information Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. The message about remedial Endress+Hauser...
  • Page 40  The Diagnostic list submenu opens. Select the desired diagnostic event with  or  and press  .  The message about the remedial measures opens. Press  +  simultaneously.  The message about the remedial measures closes. Endress+Hauser...
  • Page 44 www.addresses.endress.com...

Table of Contents