1.Product Overview
ECS-01HT1 Universal temperature controller can convert Fahrenheit, Celsius display display,
switching cooling / heating mode. The allocation of cabinet temperature sensor and defrosting control
sensor. Optional defrost relay output and copy card function.
2.operation and display panel
3.Specifications and dimensions
Installation dimension : 71mm×29mm
4.Technical parameters
1)Measuring range : -50~99℃/℉ (only refers to the sensor calibration value is set to 0)
2)Temperature resolution : 9.9~-9.9 , 0.1℃/℉ , the others,1℃/2℉
3)Measurement accuracy : -40℃~50℃ , ±1℃ , 50℃~70℃ , ±2℃ , the others : ±3℃
4)Temperature controlling range : -50~99℃/℉
5)Power supply : 220±10%(VAC) , 50/60Hz
6)power consumption : <3W
7)Rated current of the relays :
Refrigeration : 30A/220VAC , it can directly drive 1.5 HP (220VAC) compressor , single phase
Defrost: 10A/220VAC( suggest connect the max 1.4 KW electric heating wire)
8) Front panel water proof : IP65
9)The back shell water proof : None
10) Operation condition : 0℃~55℃
11) Storage condition : -25℃~75℃,
12) Relative humidity : 20%~85% (relative humidity )
5.Indicator light status description
Indicator light
Setting
Compressor
ECS-10HT1 Temperature controller instruction
or -40℉~99℉, ±2℉ , the others : ±6℉
17A/220VAC , it can directly drive 1.0HP (220VAC) compressor , single phase
Symbol
set
Controller size : 78.5mm×34.5mm×74mm
Status
On
Parameter settings
Off
working order
On
Cooling / heating
Off
Cooling / heating stoped
Flashing
Cooling / heating delay
Meaning

Advertisement

loading

Summary of Contents for Elitech ECS-10HT1

  • Page 1 ECS-10HT1 Temperature controller instruction 1.Product Overview ECS-01HT1 Universal temperature controller can convert Fahrenheit, Celsius display display, switching cooling / heating mode. The allocation of cabinet temperature sensor and defrosting control sensor. Optional defrost relay output and copy card function. 2.operation and display panel 3.Specifications and dimensions...
  • Page 2 Defrost work Defrost Defrost stop ℃ Temperature unit is ℃ Temperature unit ℉ Temperature unit is ℉ Temperature unit See the set point Check the temperature setting 6.Parameter Table Menu Functions Setting range Default Level Maximum ~Minimum Set Point Temperature setting value 0.1~10℃...
  • Page 3: Front Panel Commands

    -50~90℃ Defrost termination temperature -50~90℉ Defrost cycle 0~99hour The maximum time of defrost 1~99min rt : Display cabinet temperature It : Display start-defrost cabinet temperature Defrost status display St : Display temperature setting value dF : Display “dF” (AL+1)~99℃ Cabinet temperature upper limit alarm value (AL+1)~99℉...
  • Page 4: How To Change The Set Point

    Success of “do” 、 Download the copy card pressing the keys for 1s Failure of “Er” display Evaporator Press the response temperature Start manual defrost pressing the keys for 2s light HOW TO SEE THE SET POINT : 1) Push and immediately release the SET key, the set point will be showed and the “ ”LED starts lighting ;...
  • Page 5: Manual Defrost

    Keep pressed ▲+▼ for more than 3s,the “oF” message will be displayed and the keyboard will be locked. Keep pressed ▲+▼ for more than 3s ,the “on” message will be displayed and the keyboard will be unlocked. MANUAL DEFROST Press to view the current evaporator sensor measured temperature value.
  • Page 6 Mess. Cause Outputs and “Md” Cabinet high temperature alarm Outputs unchanged Cabinet low temperature alarm Outputs unchanged Evaporator sensor is forbidden ,display screen show the evaporator’s temperature Hot key program failure 1) When the temperature sensor is fault , it is display P1 or P2, it will recover when the problem is solved.
  • Page 7 11.Safety rules ★Danger : 1) Strictly distinguish the power wire, relay output, sensor down-lead and data line, and the relay could not be overloaded. 2) Prohibit connecting the wire terminals without electricity cut-off. ★Warning : Prohibit using this unit under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion.
  • Page 8 a proper distance. 3) When evaporator sensor is installed, the sensor should be well connected with the copper tube which is 5cm away from evaporator inlet.