Defrost
Temperature unit
Temperature unit
Check the temperature setting
6.Parameter Table
Menu
Functions
St
Temperature setting value
Hy
Hysteretic value
LS
Minimum set point
US
Maximum set point
ot
Cabinet sensor calibration
P2
Evaporator sensor selection
oE
Evaporator sensor calibration
Outputs activation delay at start
od
up
AC
Anti-short cycle delay
Compressor running time in the
mode of "Run/stop in a
Cy
proportional time"
Compressor stop time in the
mode of "Run/stop in a
Cn
proportional time"
CH
Cooling /Heating
℃/℉
CF
Ld
Default Display
On
Off
On
On
On
Setting range
Maximum ~Minimum Set Point
0.1~10℃
1~25℉
-50℃~St
-50℉~St
St~99℃
St~99℉
-9.9~9.9℃
-20~20℉
y:Enable
n:Forbidden
-9.9~9.9℃
-20~20℉
0~99min
0~50min
0~99min
0~99min
CL:Cooling
Ht:Heating
C:℃
F:℉
P1:Display the cabinet sensor
P2: Display the evaporator sensor
SP:Display the temperature
setpoint
Defrost work
Defrost stop
Temperature unit is ℃
Temperature unit is ℉
See the set point
Default
3
2
-50
99
0
y
0
0
1
15
30
CL
C
P1
Level
Pr0
Pr1
Pr2
Pr2
Pr1
Pr1
Pr2
Pr2
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2