Emerson Fisher Vonk CHV Instruction Manual page 8

Vonk choke valves
Table of Contents

Advertisement

Vonk Choke Valves
September 2019
In case of a HT version valve, the bonnet should not be insulated (this may over-heat the bonnet).
After installation, check the operation of the valve by stroking it to 'full open' and 'full close'. The position of the valve
can be indicated in the following ways:
1. Mechanical, by a dial plate showing the position of the valve. The following methods are available:
a. Percent of the full stroke of the actuator
b. Percent opening of the valve
c. Equivalent bean size in 1/64-inch increments
E
2.
lectrical limit switches indicating end of stroke of the actuator.
3. Electronic valve position transmitter, presenting the position of the valve:
a. As a 4-20 ma signal
b. As a 4-20 ma signal with 'smart' transmitter information (HART
c. As a fieldbus signal (e.g. F
Figure 2. Vonk Choke Valves Open / Throttled / Shut
OPEN
THROTTLED
SHUT
4
™ fieldbus, PROFIBUS)
OUNDATION
BODY / BONNET BOLTING
®
protocol)
BONNET SHAFT
SPRING
SOFT SEALS
BODY PROTECTING BUSH
TURNING FORK
FRONT DISK
SOFT SEALS
BACK DISK AND BEAN CARRIER
BODY
Instruction Manual
D104485X012