Etnyre Centennial Manual

Flow charts and control positions, variable width spraybar with bt-1 controls

Advertisement

Quick Links

A-130-08
Variable Width Spraybar
Centennial
BT-1 Controls
with
Flow Charts and Control Positions
E. D. ETNYRE & CO.
1333 S. Daysville Road, Oregon, Illinois 61061
Phone: 815/732-2116 Fax: Sales 815-732-7400
email: sales@etnyre.com www.etnyre.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Centennial and is the answer not in the manual?

Questions and answers

Summary of Contents for Etnyre Centennial

  • Page 1 A-130-08 Variable Width Spraybar Centennial BT-1 Controls with Flow Charts and Control Positions E. D. ETNYRE & CO. 1333 S. Daysville Road, Oregon, Illinois 61061 Phone: 815/732-2116 Fax: Sales 815-732-7400 email: sales@etnyre.com www.etnyre.com...
  • Page 3: Table Of Contents

    Transfer ............15 If you have any questions regarding this pamphlet or the Flushing ............16 operation of your unit, contact your Etnyre dealer or the E. D. Etnyre Service Department at 1-800-995-2116. Flushing Bar ..........17 Front Fill (optional equipment) ..... 18 Etnyre Spray Bar Nozzles ......
  • Page 4: Bar Suck Back Override

    Bar Suck Back Override This optional feature is designed for quick in-cab switching be- tween bar circulate and bar suck back for units equipped with au- tomatic tank and bar suck back valves. When the BAR SUCK BACK OVERRIDE switch is ON, all automatically controlled valves are set to their correct positions for BAR SUCK BACK.
  • Page 5: Control Panels

    Control Panels 1. SPRAY Switch 5. Function knob Turning this switch to ON when the When the desired operation is se- Function knob (rear panel) is turned lected through this knob, the asphalt to BAR CIRCULATE or BAR SUCK pump stops turning if the PUMP CON- BACK, opens all activated spray TROL is in AUTO, and all automatic valves.
  • Page 6: Fill Through Manhole

    The instructions represented here are a guide Rear Panel and not designed to be comprehensive. Refer Cab Panel • Function Switch to LOAD/TRANSFER position to M-114-08 Centennial Operation Manual for complete instructions. • POWER Switch OFF • POWER Switch OFF 0 FPM F T - I N 0 .
  • Page 7: Fill Through Fill Line

    • Function Switch to LOAD/TRANSFER position • POWER Switch ON and not designed to be comprehensive. Refer • POWER Switch ON • 100 GPM - adjust using to M-114-08 Centennial Operation Manual for complete instructions. VALUE switch • Push "START" switch 0 FPM F T - I N 0 .
  • Page 8: Circulate In Tank

    The instructions represented here are a • Push START switch guide and not designed to be comprehensive. • Function Switch to TANK CIRCULATE position Refer to M-114-08 Centennial Operation • 100 to 150 GPM - adjust using • POWER Switch ON Manual for complete instructions.
  • Page 9: Circulate In Bar

    • Function Switch to BAR CIRCULATE position comprehensive. Refer to M-114-08 switch or by using the VALUE switch • POWER switch ON Centennial Operation Manual for • Set spray width with One Foot switches complete instructions. • Push START switch...
  • Page 10: Spray

    • When the spray bar reaches the beginning Rear Panel comprehensive. Refer to M-114-08 of the shot, turn the SPRAY switch ON, turn Centennial Operation Manual for • Function Switch to BAR CIRCULATE position the switch OFF at the end of shot. complete instructions.
  • Page 11: Suckback Spraybar

    • Function Switch to BAR SUCK BACK position comprehensive. Refer to M-114-08 • POWER switch ON • POWER switch ON Centennial Operation Manual for complete instructions. • 200 GPM - adjust using VALUE switch • Push START switch F T - I N 0 .
  • Page 12: Handspray

    • PUMP SPEED knob zero (fully counterclockwise) and not designed to be comprehensive. Refer to • Function Switch to HANDSPRAY position • POWER switch ON M-114-08 Centennial Operation Manual for • 50 GPM - adjust using • POWER switch ON complete instructions.
  • Page 13: Handspray Suckback

    The instructions represented here are a guide • POWER switch ON and not designed to be comprehensive. Refer • Function Switch to BAR SUCK BACK position to M-114-08 Centennial Operation Manual for • 200 GPM - adjust using • POWER switch ON complete instructions.
  • Page 14: Unload

    • PUMP CONTROL switch AUTO The instructions represented here are a guide • PUMP SPEED knob zero (fully counterclockwise) and not designed to be comprehensive. Refer to M-114-08 Centennial Operation Manual for Cab Panel • Function Switch to UNLOAD position complete instructions.
  • Page 15: Transfer

    • POWER Switch ON • Function Switch to LOAD/TRANSFER position and not designed to be comprehensive. Refer • 100 GPM - adjust using • POWER Switch ON to M-114-08 Centennial Operation Manual for VALUE switch • Push START switch complete instructions. 0 FPM F T - I N 0 .
  • Page 16: Flushing

    Cab Panel • POWER Switch ON comprehensive. Refer to M-114-08 Centennial Operation Manual for • POWER Switch ON • Push START switch complete instructions. • 100 GPM - adjust using VALUE switch •...
  • Page 17: Flushing Bar

    Cab Panel and not designed to be comprehensive. Refer • POWER Switch ON • POWER Switch ON to M-114-08 Centennial Operation Manual for • Push START switch • 100 GPM - adjust using complete instructions. • WASH PUMP Switch (optional) - ON...
  • Page 18: Front Fill (Optional Equipment)

    • Function Switch to LOAD/TRANSFER position comprehensive. Refer to M-114-08 • POWER Switch ON • POWER Switch ON Centennial Operation Manual for • 100 GPM - adjust using • Push START switch complete instructions. VALUE switch •...
  • Page 19: Etnyre Spray Bar Nozzles

    Etnyre Spray Bar Nozzles Ref. Part No. Description Application Application US Flow Gallons Per (Metric) Liters Per Gallons Per Square Yard Square Meter Minute Per Foot 3353788 V Slot Tack Nozzle .05 - .20 .23 - .91 3.0 to 4.5...

Table of Contents