1. Allgemeine Sicherheitsvorschriften
Beim Umgang mit Produkten, die mit elektrischen Spannungen in Berührung kommen,
müssen die gültigen VDE / IEC / EN Vorschriften beachtet werden. Besonders sei auf
folgende Vorschriften hingewiesen: VDE 0100, VDE 0550 / 0551, VDE 0711, VDE
0860, IEC 664, IEC 742, IEC 570, IEC 65
Bei Nichtbeachtung der Bedienungsanleitung oder der Anschlussvorschrift, z.B. bei
Vertauschen der Anschlussklemmen, kann das Gerät oder die Anlage beschädigt
werden und der Betreiber verliert seinen möglichen Haftungsanspruch.
Werkzeuge dürfen an Geräten, Bauteilen oder Baugruppen nur benutzt werden, wenn
sichergestellt ist, dass die Geräte von der Versorgungsspannung getrennt sind und
interne elektrische Bauteile entladen bzw Akkus ausgebaut sind.
Vor dem Öffnen des Gerätes den Netzstecker ziehen und sicherstellen, dass das Gerät
spannungslos ist und bleibt. Bauteile, Baugruppen oder Geräte dürfen nur in Betrieb
genommen werden, wenn sie vorher in ein berührungssicheres Gehäuse eingebaut
wurden. Während des Einbaus müssen sie stromlos sein.
Spannungsführende Kabel oder Leitungen mit denen das Gerät, das Bauteil oder die
Baugruppe verbunden sind müssen stets auf Isolationsfehler oder Bruchstellen
untersucht werden. Bei Feststellen eines Fehlers in der Zuleitung muß das Gerät
unverzüglich aus dem Verkehr genommen werden, bis die defekten Leitungen
ausgewechselt worden sind.
Der Anwender hat dafür Sorge zu tragen, dass die angegebenen Gerätedaten nicht
überschritten werden.
Wenn aus den vorgelegten Beschreibungen für den Anwender oder Erwerber nicht
eindeutig hervorgeht, welche Kennwerte für ein Gerät oder Bauteil gelten, so muss
stets ein Fachmann um Auskunft ersucht werden.
Im übrigen unterliegt die Einhaltung von Bau- und Sicherheitsvorschriften aller Art (VDE,
TÜV, Berufsgenossenschaften ) dem Anwender / Käufer.
Die RS-232-Schnittstelle ist (anders als RS-485)
nicht von der DC-Seite potentialgetrennt.
Bei Anschluss z.B. an Rechner muss für Potential-
trennung gesorgt werden!
Verbraucher (z.B. Schütze, Motoren, Magnetventile, etc.) die
nicht ordnungsgemäß nach den relevanten Richtlinien
entstört sind (z.B. Varistoren, RC-Glieder, etc), können zur
Störung bzw. Zerstörung des Netzgerätes führen.
Für den ordnungsgemäßen Betrieb des Gerätes ist ein
Überspannungsschutz nach VDE0185-4 / EN62305-4,
eine Vorsicherung, gemäß Tabelle, und optional ein
Netzfilter vorzusehen.
Please observe carefully!
Zum Erreichen der maximalen Ladekapazität bitte
beachten:
1) Bei der ersten Inbetriebnahme des Ladereglers
die Akkus mindestens 24 Stunden laden!
2) Die Akkus durch mindestens 3 volle Lade- und
Entladezyklen bei gleichzeitiger Stromentnahme
(ca. 60%) konditionieren!
Ansonsten kann es vorkommen, dass schon nach wenigen
Minuten die LED "Akku voll" leuchtet, obwohl der Akku
noch nicht vollständig geladen ist.
!
For reaching the maximum capacity it is strongly
recommended:
1) Charge the batteries for at least 24 hours
when using the charge controller for the very first time!
- konform
2) Condition the batteries by at least 3 full charge and
discharge cycles with simultaneous current drain
(approx. 60%)!
Otherwise, the "Akku voll" LED may light up after just a
few minutes, even though the battery is not yet fully
charged.
www.feas.de

1.General safety instructions

When working with products which are in contact to dangerous electrical voltages,
attention must be payed to the relevant valid VDE / IEC / EN regulations. Especially
with reference to the following regulations:
VDE 0100, VDE 0550 / 0551, VDE 0711, VDE 0860, IEC 664, IEC 742, IEC 570,
IEC 65
In case of non-observance of this instructions the unit or other equipment might be
damaged and no warranty or liability could be accepted.
When it is necessary to use tools on the device component parts or subassemblies
make sure that the power is disconnected from the device and all capacities are
discharged.
Before opening the device disconnect the power cord and make sure that the
contacts are not energized. It is only allowed to take component parts,
subassemblies or devices into operation if they are mounted in an insulated housing.
During installation all devices have to be disconnected from power sources.
Power cords and leads which are connected to the device, components or
subassemblies have to be inspected for damaged insulation. If a failure is detected
the device or the subassembly has to be put out of service at once. It is not allowed
to take the device or the subassembly into operation before replacing the damaged
power cord.
It is up to the user's responsibility that the specification limits of the device are not
exceeded.
If the user is not fully able to relate the technical guidelines, a technical adviser has
to be asked for information.
The observance of construction requirements and safety regulations (VDE, IEC,
employers liability insurenance i.e.) is subject to the user/customer.
RS232 interface (unlike the RS485 interface) is
not electrically isolated from the DC side.
When connecting e.g. to a computer potential separation
must be ensured!
Consumers (e.g. contactors, motors, solenoid valves etc.)
which have not been correctly interference-suppressed in
accordance to the relevant guidelines (e.g. varistors, RC
elements, etc.) may cause power supply regulation to
malfunction.
For proper operation of the device provide an
overvoltage protection, according VDE0185-4 /
EN62305-4, an input fuse as shown in table and
optionally a line filter.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LDR8024-RS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FEAS LDR8024-RS

  • Page 1 Für die Modelle: Complementing the: (approx. 60%)! - LDR8024-RS - Otherwise, the "Akku voll" LED may light up after just a ® few minutes, even though the battery is not yet fully Postfach 1521 Telefon: 04102 - 42082 charged.
  • Page 2 2. Funktionsweise 2. Mode of operation 5.3 RS-232/RS-485 Buchsenbelegung 5.3 RS-232/RS-485 jack assignment Das LDR ist ein Akku-Modul zur Überbrückung von Netzausfällen The LDR is a buffer-modul to buffer the DC-circuit in case of power im DC-Versorgungsnetz. Die Versorgungsdauer hängt von der blackouts.
  • Page 3 8. Bildschirmanzeigen 8. Screen displays 7. RS-232 / RS-485 Betrieb 7. RS-232 / RS-485 Operation Value range / definition Über die RS-232/RS-485-Schnittstelle gibt das LDR Via the RS-232 / RS-485 interface the LDR sends Wertebereich / Bedeutung Parameter Parameter Statusmeldungen aus und nimmt Kommandos entgegen. status messages and accepts commands.
  • Page 4 The screen displays for RS-232 and RS-485 differ only in the unterscheiden sich nur in der Kopfzeile: header: RS-232: “FEAS BATTERY CONTROL – RS232“ RS-232: "FEAS BATTERY CONTROL - RS232" RS-485: „FEAS BATTERY CONTROL – RS485“ RS-485: "FEAS BATTERY CONTROL - RS485"...
  • Page 5 Pufferzeiteinstellung - Reduzierung der Zeit Setting Remaining Time - decreasing time 11. RS-232/RS-485-Einstellungen im Detail 11. RS-232/RS-485 Settings in detail „Schlafen legen“ im Pufferbetrieb Switching to „sleeping“ in buffering mode Im Pufferbetrieb kann das LDR zur Schonung des Akkus In buffer mode, the LDR can be deactivated ("sleep mode") to deaktiviert werden (“Schlafen gelegt“).
  • Page 6 Surge protective Accu 2 device devices devices devices linefilter Remove here the e.g. SNT230 Typ1 Typ2 Typ3 e.g. 24V-Version screws M4 with >1300V >600V <600V FEAS NFK Inbus-key(SW2,5)! Accu 1 Blitz- und Transientenschutz EMV Schutz EMC protection lightning and overvoltage protection...
  • Page 7 Gewicht ca. 12,2kg Weight approx. 12,2kg Line off, Ta > 53°C. Netz aus, Ta > 55°C LDR8024-RS Kapazität in % zur Nennkapazität bei verschiedenen aus / off Line off, Ta > 55°C. Eingangsspannung 85V ...270V / 120V ..400V Input voltage Netz aus, Ta <...
  • Page 8 30s Ÿ Kurzschlussfest, überlast- und leerlaufsicher Ÿ Ausgang potentialfrei nach VDE 0551 Ÿ Sicherheit nach VDE, EN, UL und CSA Postfach 1521 Telefon: +49 4102 42082 E-Mail: verkauf@feas.de D - 22905 Ahrensburg Fax: +49 4102 40930 Internet: www.feas.de © 2019...

Table of Contents