KSB Amamix direkt Installation & Operating Manual page 31

Submersible mixer
Table of Contents

Advertisement

Goodnal STP ST041 Biological Treatment (KSB Amamix Direct Installation and Operation Manual) Vendor Manual
Q-Pulse Id VM385
7 Servicing/Maintenance
WARNING
Contamination of fluid handled by lubricant
Hazardous to persons and the environment!
▷ Using machine oil is only permitted if the oil can be disposed of properly.
7.2.1.5.2 Quantity of lubricant
Table 10: Lubricant quantity
Size
200 G
200 C
300
400
600 C
600 G
7.2.1.5.3 Draining the lubricant
WARNING
Lubricants posing a health hazard and/or hot lubricants
Hazard to persons and the environment!
▷ When draining the lubricant take appropriate measures to protect persons and
the environment.
▷ Wear safety clothing and a protective mask, if required.
▷ Collect and dispose of any lubricant.
▷ Observe all legal regulations on the disposal of fluids posing a health hazard.
WARNING
Excess pressure in the lubricant reservoir
Liquid spurting out when the lubricant reservoir is opened at operating temperature!
▷ Open the screw plug of the lubricant reservoir very carefully.
903.01
411.01
903.02
411.02
Fig. 8: Draining the lubricant
1. Position the submersible mixer as shown.
2. Place a suitable vessel under the screw plug.
3. Remove screw plugs 903.01 and 903.02 with joint rings 411.01 and 411.02, and
drain off the lubricant.
4. Close screw plug 903.02 again, fitting a new joint ring 411.02.
Amamix® direkt
Active 29/10/2013
Lubricant quantity
0.3 l
0.4 l
0.4 l
0.8 l
1.4 l
2.4 l
31 of 52
Page 31 of 52