Response Time - P3 International Kill A Watt PS Operating Manual

Advertisement

Specifications:
ITEM
RMS voltage
RMS current
Active power
KWH1
Power Factor
Leakage Current
1
Elapsed Time
Abnormal
Under Voltage
Voltage
Protection
Over
Voltage
Protection
Over Current Breaker
Electronic
Short
Breaker
NFB
No Load Detector
Surge Protection
EMI Filter
1
Display will flash when maximum count is reached for KWH, Elapsed Time
Maximum relative humidity 80% for temperature up to 31℃ decreasing linearly to 50% relative humidity at 40℃
Shop for P3 products online at:
RANGE
108.0~132.0 Vrms
0.0~15.0Arms
0.0~1980 Watt
0.0~9999 KWH
0~100%
0~30mA
00Day/00Hour~9999Day/23Hour
00Hour/00Min~23Hour/59Min
Output Off if Vac<98.4V (Rating-18%)
Then On if Vac>102V(Rating-15%)
Output Off if Vac>135.6V(Rating+13%)
Then On if Vac<132V(Rating+10%)
Programmable
2A,5A,10A,15A
Active Current
Off:<0.2W : On:>0.2W
Maximum energy
Dissipation (Joules)
(L-N,L-G&N-G)
Maximum Clamping Voltage
Maximum Surge Current
Up to 20db for 100K to 20MHz
Technical Specification
Indoor use only
Altitude up to 2000m
Temperature 5℃ to 40℃
Mains supply voltage fluctuations not to exceed ±10% of the nominal voltage
Pollution Degree 2
Installation category II
Specification
Voltage rating:
Power consumption:
Power cord:
W/H/D
Weight
PowerMeterStore
www.
ACCURACY
Typ.
Max.
0.1%
0.4%
0.5%
1%±0.1A
2%± 5w
1%
1%
2%± 5w
PF=W/Vrms*Arms
±1mA
30ppm
0.1%
0.4%
0.1%
0.4%
0.5%
1%±0.1A
Ipk>150A
LoadAmp=100%(15A)
LoadAmp=150%(22.5A)
LoadAmp=200%(30A)
LoadAmp=400%(60A)
LoadAmp=600%(90A)
±0.1W
2040 J
359 V
60000A
120Vrms ± 10% , 60Hz
1.0W
1.8m
320mm x 53mm x 78mm
450 g (without power cord)
.ca

RESPONSE TIME

Action
Recovery
1sec
1sec
1sec
1sec
1sec
1sec
1Hour
1Min
1sec
3sec (Auto)
2sec
Manual
<0.1sec
---
1Hour
Manual
4~40sec
0.42~5sec
0.1~1.8sec
3sec
3sec
<50ns
N/A