Page 1
P4320 Kill A Watt Operating Manual Thank you for purchasing the P4320 Kill A Watt™ PS Relocatable Power Tap / Transient Voltage Surge Suppressor. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correct usage.
Page 2
Safety Instructions Å The lightning flash with arrowhead, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Page 3
Power-Cord Protection – Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product. Lightning –...
Page 4
Product Functions: 1. Power Strip: 8 outlets, Spike-free switch. 2. Multi-Meters: Voltage, Current, Active Power, Power Factor, KWH, Leakage Current, Elapsed Time. 3. Protection: Abnormal Voltage, Over Current, Over Load, Surge. 4. Programmable Breaker Current: User adjustable 2, 5, 10, or 15A breaker. 5.
Page 5
Feature Locations Display Panel Quick Start Guide: Use these quick start instructions to get up and running in just a few minutes. Be sure to review all the operating instructions later to ensure full enjoyment of the product. 1. Connect the Kill A Watt™ PS unit to the outlet and the appliance to the unit. 2.
Installation: 1. Remove the protective film (if any) covering the LCD meter display by pulling the tab marked “REMOVE BEFORE USE”. 2. Turn off all appliances before connection to the unit and remove their power cords from the outlet. Connect the Kill A Watt™ PS unit to the outlet and the appliances to the unit. Use the widely spaced outlets for wall transformers 3.
Page 7
appliance power consumption (in Watts) with the currently measured power factor (in %), the maximum measured watts/PF (indicated by the MAX icon) and the minimum measured watts/PF (indicated by the MIN icon). The display will return to the currently measured values after a few seconds. Pressing and holding the Watt/PF key for a few seconds will delete the memorized MAX/MIN values.
Page 8
3. Over Current mode: When the current load presented by the connected appliances exceeds the setting on the Max. Amps switch, the unit will switch to Over Current mode. The power will be switched off to the 8 outlets. The red LED in the OFF switch will flash. The LCD will display the protected current value.
Page 9
Troubleshooting: Item Symptoms LCD display is flashing Over Current icon on LCD is flashing and audible alarm is sounded, output is off and the red LED in the OFF key is flashing Over Load icon on LCD is flashing and audible alarm is sounded, output is off and the red LED in the OFF key is flashing...
Display will flash when maximum count is reached for KWH, Elapsed Time P3 INTERNATIONAL CORPORATION ("P3") warrants to the original retail purchaser only, that its product is free from defects in material or workmanship under the condition of normal use and service for a period of six (6) months from the date of purchase. In the event that a defect, malfunction or failure occurs or is discovered during the warranty period, P3 will repair or replace at its option the product or component part(s) which shall appear in the reasonable judgment of P3 to be defective or not to factory specifications.