Thank you for purchasing the P4330 Kill A Watt™ PS Relocatable Power Tap / Transient
Voltage Surge Suppressor. This operating manual will provide an overview of the product,
safety instructions, a quick guide to operation, and complete instructions for correct usage.
Take the time to completely review these instructions as well as all safety warnings to ensure
your best use of the product.
Now you can protect your valuable electronics and find out what they are actually costing you.
Simply connect these appliances to the Kill A Watt™ PS and it will assess how efficient they
are while the built-in surge protection keeps them safe. Advanced features such as over
current, over voltage, and no load detection provide clean safe power to your expensive
equipment. Check the quality of your power by monitoring Voltage, Amperage, KWH, Current
Leakage and more. Now you'll know how much power your entire computer of home theater
system is using. With the innovative Kill A Watt™ PS you'll have peace of mind in more ways
than one.
PowerMeterStore
1.877.766.5412
www.
.ca
Shop for P3 products online at:

Advertisement

loading

Summary of Contents for P3 International Kill A Watt PS

  • Page 1 P4330 Kill A Watt Operating Manual Thank you for purchasing the P4330 Kill A Watt™ PS Relocatable Power Tap / Transient Voltage Surge Suppressor. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correct usage. Take the time to completely review these instructions as well as all safety warnings to ensure your best use of the product.
  • Page 2 Safety Instructions Read Instructions – All the safety and operating instructions should be read before the product is operated. Retain Instructions – The safety and operating instructions should be retained for future reference. Heed Warnings – All warnings on the product and in the operating instructions should be adhered to. Follow Instructions –...
  • Page 3 Power-Cord Protection – Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product. Lightning –...
  • Page 4 Product Functions: 1. Power Strip: 10 outlets, Spike-free switch. 2. Multi-Meters: Voltage, Current, Active Power, Power Factor, KWH, Leakage Current, Elapsed Time. 3. Protection: Abnormal Voltage, Over Current, Over Load, Surge. 4. Programmable Breaker Current: User adjustable 2, 5, 10, or 15A breaker. 5.
  • Page 5 Feature Locations 10 Normal Outlets NFB Short Breaker Elapsed Time KWH/Leakage Watt/PF Max.Amps Volt/Amp Display Panel AC Voltage AC Power Up to date Max. Kilo - Watt - Hour Elapsed Days Over Over current Volt Current Watt No Appliance connected NO Load AC Current Over 15A Max Current...
  • Page 6 7. Pressing the Watt/PF Key will cycle through currently measured active power (Watts), power factor (%) and Maximum/Minimum measured values. 8. Pressing the KWH/Leakage key will cycle through cumulative kilowatt hours (KWH), currently measured leakage current (mA) and Maximum/Minimum measured values (leakage current only). 9.
  • Page 7 Retained Output Mode: 1. If the power supply to the Kill A Watt PS unit is interrupted and then restored, the LCD panel will flash to alert the user to an interruption. Press any of the function keys to stop the LCD from flashing. The unit will resume the output mode at time of power interruption.
  • Page 8 Protection Functions: 1. Max. Amps switch: This switch on the control panel allows the user to optionally select the maximum current (Amps) the unit will deliver to the attached appliances without automatically shutting off. Use a small screwdriver to select 2A, 5A, 10A or 15A (factory default). Setting Procedure: a.
  • Page 9 6. Ground OK, Wiring OK detection: When you connect the unit to a wall outlet, the unit will check the structure wiring to determine and wire faults. The unit checks the Line, Neutral and Ground wiring. Under normal conditions, “Ground OK” and “Wire OK” icons will display on the LCD. If Line or Neutral are in the wrong positions, the “Wire OK”...
  • Page 10 Troubleshooting: Item Symptoms Action Description LCD display is flashing Press any key 1. This is normal operation after you plug the unit into a wall outlet. 2. AC power to the unit has been interrupted. Over Current icon on LCD Press Reset key (OFF key), check &...
  • Page 11: Response Time

    Specifications: ACCURACY RESPONSE TIME ITEM RANGE Typ. Max. Action Recovery RMS voltage 108.0~132.0 Vrms 0.1% 0.4% 1sec RMS current 0.0~15.0Arms 0.5% 1%±0.1A 1sec 2%± 5w Active power 0.0~1980 Watt 1sec KWH1 0.0~9999 KWH 2%± 5w 1sec Power Factor 0~100% PF=W/Vrms*Arms 1sec ±1mA Leakage Current...
  • Page 12 LIMITED WARRANTY P3 INTERNATIONAL CORPORATION ("P3") warrants to the original retail purchaser only, that its product is free from defects in material or workmanship under the condition of normal use and service for a period of six (6) months from the date of purchase. In the event that a defect, malfunction or failure occurs or is discovered during the warranty period, P3 will repair or replace at its option the product or component part(s) which shall appear in the reasonable judgment of P3 to be defective or not to factory specifications.