AEG PX71-265WT User Manual page 15

Table of Contents

Advertisement

Available languages

Available languages

Dry mode
In this mode you do not need to use the
exhaust adaptor hose, BUT the water
collected must be discharged. See 7.3
Drainage Section.
1. Press the "Modes" button until the
"Dry" indicator is lit.
2. The fan will run at low speed and
the display will show the room
temperature.
3. Keep doors & windows closed
for
4. Connected drain hose. See Drainage
section.
Auto mode
Always have the exhaust hose attached
in this mode.
When you set the air conditioner in Auto
mode, it will automatically select cooling,
heating (inapplicable for cooling only
models), or fan only operation depending
on what temperature you have selected
and the room temperature. The air
conditioner will control room temperature
automatically round the temperature
point set by you.
Under AUTO mode, you can not select
the fan speed.
1. Press the "Modes" button until the
"Auto mode" indicator lights.
After the "Auto mode" is selected the unit
will run automatically according to the
actual room air temperature.
1.
2.
3
Selecting fan speed
You can select the desired fan speed, by
pressing the "Fan speed" button. The fan
speed will change in the sequence: "Auto
Fan", "High", "Mid", "Low".
After choosing the fan speed as
"Auto Fan", "High", "Mid" or "Low",
the corresponding fan speed
indicator light will illuminate.
Under Auto and Dry mode, you
can not select the fan speed.
DEACTIVATE WIFI MODULE:
holding the "Connect button" and " - "
synchronously 3 seconds. Press the
"Connect button" again to activate the
10 seconds for the module to initiate again.
7.2 Fault code
If the display reads "A5", the room
temperature sensor has failed. Contact
your Authorized AEG Service Centre.
If the display reads "E5", the evaporator
temperature sensor has failed. Contact
your Authorized AEG Service Centre.
If the display reads "E4", the display panel
communication has failed. Contact your
Authorized AEG Service Centre.
If the display reads "P1", bottom tray is full.
Carefully move the unit to a drain location,
remove the bottom drain plug and let the
water drain away. Restart the machine
until the "P1" symbol disappears. If error
repeats, call for service.
If the display reads "E7", the indoor motor
has failed. Contact your Authorized
AEG Service Center.