1.6 Changing of fixtures or tooling must be done with the power source disconnected. 1.7 The F1300N Rotary Table should only be operated in an environment of 0 to 40 degrees centigrade and humidity of 20 to 95 percent with no condensation.
F1300N Rotary Table Operating Manual Section 2: Setup Rev A, February 2018 Package Contents In addition to this operating manual, the following items should be included with the rotary table: Moveable Post Y axis Main Unit (mounting screws) X Axis Post...
F1300N Rotary Table Operating Manual Section 2: Setup Rev A, February 2018 Back View Sensor connector I/O port Cylinder in Cylinder out Mains air out Power switch Ext. Control Serial plate Fuse Dispense air out RS232 port Exhaust out port...
F1300N Rotary Table Operating Manual Section 2: Setup Rev A, February 2018 Unpacking the Rotary table • Unpacking the rotary table will require a minimum of two people. Do not attempt to lift the rotary table without assistance. • Always lift the rotary table from the base.
Section 2: Setup Rev A, February 2018 Setup The F1300N Rotary tables are available in many different configurations. The configuration of each machine and the accessories used with each system will depend on the customer’s application. The steps required to setup a system using a 30 cc or 55 cc barrel are listed below.
Page 14
F1300N Rotary Table Operating Manual Section 2: Setup Rev A, February 2018 3.4. When the Rotary table base is set on a secure work table, take the X axis mounting post and fix it to the mounting table top, use the M5 x 25 cap head screws supplied with the post.
F1300N Rotary Table Operating Manual Section 2: Setup Rev A, February 2018 Drive cyclinder Setup To correctly set up the drive cylinder for application usage: After plumbing in the mains air supply to the 8mm fitting on the back of the rotary table, and the 4mm cylinder in and clyinder out pipes into the correct flow relugator fittings.
F1300N Rotary Table Operating Manual Section 3: Teaching Overview Rev A, February 2018 Teaching Overview A program consists of a series of parameters stored in the main unit memory. Each parameter is stored in a numbered program memory. The programs consist of motor rotation angle, speed and control delays.
F1300N Rotary Table Operating Manual Section 3: Teaching Overview Rev A, February 2018 Rotary Table Menu Summary Production Screen Below is a list of functions, which are found under the Production Screen: Function Description Dispense Angle Sets the parameter for the angle of rotation of the motor...
Page 19
F1300N Rotary Table Operating Manual Section 3: Teaching Overview Rev A, February 2018 Function Description setup screen This button opens the settings menu on the HMI touch screen. This menu is password protected. Test Screen This button opens the Test screen on the HMI touch screen.
F1300N Rotary Table Operating Manual Section 3: Teaching Overview Rev A, February 2018 Test Screen Below is a list of functions, which are found under the Test Screen: Function Description Shows a red or green light to show when this function is Cylinder Up active or in active.
Page 21
F1300N Rotary Table Operating Manual Section 3: Teaching Overview Rev A, February 2018 Function Description Spray On/Off This button activates the atomizing air solenoid in the rotary table. On, the solenoid is open and atomizing air is on. Off, the solenoid is closed and the atomizing air is off.
F1300N Rotary Table Operating Manual Section 3: Teaching Overview Rev A, February 2018 Setup Screen Below is a list of functions, which are found in the Setup Screen: Function Description This opens a drop-down menu to choose a language to Language set the machine in.
Page 23
F1300N Rotary Table Operating Manual Section 3: Teaching Overview Rev A, February 2018 Function Description Shows the total number of Minutes the rotary table has Total On Time been active. Shows the total number of complete dispense cycles the Total Cycles rotary table has run.
F1300N Rotary Table Operating Manual Section 4: Programming Example Rev A, February 2018 Instruction Display Shows Turn on Rotary table and touch the HMI screen to open the production Screen Open the test screen and press the cylinder on/off, to turn it “ON” and drive the cylinder to the bottom position.
F1300N Rotary Table Operating Manual Section 4: Programming Example Rev A, February 2018 Optimizing Dispense Cycle Ways to improve and adapt the quality and finish of the dispense bead. Dispense Pressure: An increase in the dispense pressure will increase the flow rate of materials from the mounted syringe, cartridge or valve being used for the application.
F1300N Rotary Table Operating Manual Section 5: Error Messages and Specifications Rev A, February 2018 Error Messages Door Error This is the error message show when there is a fault or breaking in connection in the Door switch or Emergency Switch in the Ext.
Page 41
F1300N Rotary Table Operating Manual Section 8: Maintenance and Periodic Inspection Rev A, February 2018 Check Cycles and Methods General Consideration It is essential to correctly and periodically inspect and maintain the rotary table to prevent unexpected failures or malfunctions, thus ensuring safe operation and lengthening the machine’s life.
Page 42
F1300N Rotary Table Operating Manual Section 8: Maintenance and Periodic Inspection Rev A, February 2018 Check Methods Check Point Check Action (see if) Corrective action Tilt or deviation of axis The rotary table tip is Reset the tip to the correct...
Page 43
F1300N Rotary Table Operating Manual Section 8: Maintenance and Periodic Inspection Rev A, February 2018 Accuracy and precision If the tip is out of Contact agent position in any axis Inspect the tightness of the direction axis brackets and tighten if...