Refrigerant Cycle Diagram - Toshiba RAS-10BKV-E1 Service Manual

Table of Contents

Advertisement

7-1. Refrigerant Cycle Diagram

P
Pressure measurem
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
7. REFRIGERANT CYCLE DIAGRAM
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
ASK89D53UEZ
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
Temp. measurement
T1
TC
TA
TO
TE
NOTE :
- 19 -
FILE NO. SVM-17030
Max.
Min.
Chargeless : 15m
Strainer
Pulse Modulating
valve at liquid side
Strainer
10k Refrigerant amount : 0.52kg
13k Refrigerant amount : 0.58kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
: 15m
: 2m