(For AC fan motor)
<Inspection procedure>
1. Remove the front panel. (Remove 2 screws.)
2. Remove the cover of the fan motor lead wires.
3. Check AC voltage with CN10 connector while the fan motor is rotating.
NOTE :
• Using a tester, measure the resistance value of each winding coil.
• Use a thin test rod.
SJM-240-25
• Do not disconnect the connector while the fan motor is rotating.
• For P.C. board side, proceed to the item "Only indoor fan does not operate"
of "Judgment of Trouble by Every Symptom".
P.C. board
Position (P.C. board)
Between
(Black) -
3
Between
(Black) -
3
Between
(Red) -
1
WHI
5
CN10
BLK
3
3
3
5
5
RED
1
1
1
BRW
3
3
3
CN11
GRY
2
2
2
YEL
1
1
1
(Red)
1
(White)
5
(White)
5
Resistance value
120.6 ± 8.4 Ω
244.2 ± 17 Ω
364.8 ± 25.5 Ω
- 74 -