1. Cooling operation
Room temperature setting range is 61 ~ 90˚F (16 ~ 32˚C).
Room temperature indication range is 32 ~ 122˚F (0 ~ 50˚C).
State of operating is as shown below.
Room
temperature
+2˚F (+1.0˚C)
Setting
temperature
-2˚F (-1.0˚C)
Compressor
Fan speed
A. When the room temperature is 2˚F (1˚C) higher than the setting temperature, the compressor operates at
least for 150 seconds.
If the room temperature drops 2˚F (1˚C) lower than the setting temperature, the compressor stops.
B. For protection of the compressor, it will not restart at least for 150 seconds after it has stopped.
C. In the condition that the Setting temperature +2˚F (+1˚C) > Room temperature > Setting temperature -2˚F
(–1˚C), the compressor operates for more than 150 seconds.
If the room temperature drops more than 2˚F (1˚C) from the setting temperature, the compressor stops.
D. When the room temperature is 2˚F (1˚C) lower than the setting temperature, the compressor will not start.
E. The fan will operate at the selected fan speed.
2. Dehumidifying operation
When the room temperature is lower than 77˚F (25˚C) (setting temperature), the unit enters in the dehumidifying
operation.
Changes in the dehumidifying control
77˚F (25˚C)
72˚F (22˚C)
66˚F (19˚C)
More than
150 seconds
ON
OFF
Selected
Selected
fan speed
fan speed
Room
temperature
Cold wind
Selected
fan speed
Low
Low
Low
8
More than
150 seconds
ON
OFF
Selected
Selected
fan speed
fan speed
fan speed
A: Dry
B: Dry
C: Dry
ON
OFF
Selected
Selected
fan speed
79˚F (26˚C)
Cool mode ON