LED Light Instruction

CELL: GOOD LED ON: The cell is good and producing chlorine.
INSPECT CELL RED: The cell needs to be inspected. The blades may
have calcium. The cell is not producing chlorine.
FLOW: GOOD FLOW LED ON: Sufficient water flow to produce
chlorine.
NO FLOW LED FLASHING: There is water flow. Continuous
detection of water for one minute is necessary.
SANITIZE OUTPUT SETTING: Press the button MIN and MAX,
10% for each setting.
SUPERCL /SALINITY: SHORT PRESS: Show
the salinity
LONG TIME PRESS: Enter into SuperChlor
mode, long time press again to exit setup.
SuperChlor mode will auto-exit after 24 hours.
GENERATE: The cell is operational and ready.
COLD-WATER: It warns water temperature either
below 10℃ or above 50℃--system off.
SALT: GOOD LED ON: Good salt. It shows the
Ideal Salinity: 2800 PPM to 4500 PPM
INSPECT SALT RED ON: Salt Level below 2300
PPM or above 6000 PPM
INSPECT SALT RED (flashing): Salt Level:2300
PPM to 2800 PPM/4500 PPM to 6000 PPM