Measuring the Energy Consumed - 2
To use SP8941 to calculate the energy
consumed:
At the start of the measurement period, read the
values of SP8941 001 to 005.
At the end of the measurement period, read the
values of SP8941 001 to 005 again.
Find the amount of time spent in each mode
(subtract the earlier measurement from the later
measurement).
Multiply this by the power consumption spec for
each mode.
Convert the result to kWh (kilowatt hours)
Slide 85
Here is an example calculation.
Power
Consumption
Spec (W):
Data: a
① Operating
mode
1081.8
② Ready
mode
(stand by)
214.0
③ Energy
mode
(Panel off)
214.0
④ Low
power
mode
153.0
⑤ Off
/Sleep
mode
7.0
Total Time of Data: d ( min. )
Total Time of Data: d/60min. (Hour )
Total Power Consumption of Data: e (W min.)
Total Power Consumption of Data: e / 60min./ 1000W (KW H)
Energy Saver Modes
SP8941:
Value at
Machine
Start (min)
Status
Data: b
001:
Operating
Time
21089.0
002:
Standby
Time
306163.0
003
Energy Save
Time
71386.0
004:
Low power
Time
154084.0
005:
Off mode
Time
508776.0
85
Value at
Amount of Time
End (min.)
(Data:b - Data: c)
(min.)
Data: d
Data: c
21386.0
297.0
308046.0
1883.0
75111.0
3725.0
156340.0
2256.0
520377.0
11601.0
19762.0
329.37
MT-C4 Training
Power
Consumption
(Data:a x Data:d)
(Wmin.)
Data: e
321294.6
402962.0
797150.0
345168.0
81207.0
1947781.60
32.46