KEEP YOURSELF SAFE
1. Do not open the puri er for cleaning or for any replacements. This can be done only by a
quali ed company personnel or an authorized agent.
2. Do not plug or unplug the power cord with wet hands to avoid any untoward accident
due to electrical shock or re.
3. Do not splash the ltration system with water while cleaning.
4. Do not put heavy or sharp objects on the puri er.
5. Never put the cord near stoves or heaters.
6. If the power cord is damaged, it must be replaced and not used again.
7. Always switch-o the "Ball Valve" and electrical power in case you notice any leakage
from the puri er or you are going out of home for more than 2 days.
8. Ensure input pressure is more than 10 PSI and less than 30 PSI ***
9. In case UV lamp breaks, carefully sweep all the fragments, wipe the area with a wet towel,
and dispose all the fragments including the used towel in a sealed plastic bag. Open
windows to allow room to ventilate. Do not use vacuum cleaner. Hand over the bag to
the service technician for proper disposal of the same when he visits to replace UV lamp.
10. In case of any smoke or burning smell, switch-o power, remove the plug immediately
and call us at 1860-210-1000.
*** If it is more than 30 PSI, you need to use 'Pressure reducing Valve' which must be bought at an additional cost. If the
pressure is less than 10 PSI then you need to buy 'Pressure enhancing Pump' which can be bought at an additional cost.
Ensure you buy them from the authorized service personnel of Pureit.
CLEANING AND MAINTENANCE
SF (Sediment Filter)
STEP 1 :
Close the ball valve
before opening ESF
housing for cleaning
STEP 2 :
Remove the water
inlet tube which is
attached to the housing
STEP 3 :
Rotate the housing
clock-wise and remove it
completely from the cap
STEP 4 :
Take out the grey
coloured Carbon Sleeve
and the Sediment Filter
from the housing
ATTENTION
• Close the ball valve before opening SF housing for cleaning.
• Please do not use any abrasive / pointed tool to clean the Sediment
Filter as it may damage the Sediment Filter.
• In case you observe the rubber ring is dirty, clean the rubber ring &
x it on the housing again properly.
• Clean the inner portion of the housing as well.
• If required, a Spanner for opening ESF housing can be bought from
Pureit service technician.
STEP 5 :
Clean the Sediment Filter
under jet of water,
rub by hand / tap gently
to clean
STEP 6 :
After cleaning the Filter,
put it back in the housing
and then put the grey
coloured Carbon Sleeve
back into the housing
STEP 7 :
Insert the housing inside
the cap and rotate it
anticlockwise to engage
the threads Ensure the
housing is tightened till
it's original marking
STEP 8 :
Connect the water
inlet tube to the housing
4
Need help?
Do you have a question about the Pureit Copper+ Mineral RO+UV+MF and is the answer not in the manual?
Questions and answers