Poor rinsing result due to low
water production / throughput
Unpleasant odours in water
* Starting with Lot No. 70 600 001, the RoMatik 150 automatically starts when a malfunction arises because
of water pressure that is too low.
The RoMatik 150 can also be manually restarted by pressing the calibration button until the "filter I" and
"stop" LEDs go out.
89005232-05
03/12 sch
Cause of error
Filter II needs replacing
Note: this indicator lights up after a
maximum of 6 months or 1000 hours
of permeate production
Indicates reduced water quality
Error in the water quality measuring
device
Error in the water quality measuring
device
Membrane may be clogged
Error in control system
RoMatik 150 has been disconnected
from the water or power supply
Microbiological processes (due to
lack of flushing) have produced un-
pleasant odours in the water
Water pressure that is too low
Winterhalter Gastronom GmbH
Tettnanger Str. 72
D-88070 Meckenbeuren
Remedy
Notify Winterhalter
after-sales service
Notify Winterhalter
after-sales service
Notify Winterhalter
after-sales service
Notify Winterhalter
after-sales service
Notify Winterhalter
after-sales service
RoMatik automatically
starts after 3 minutes,
after 20 minutes and after
*
4 hours