Troubleshooting

Problem
Possible Cause
PCBA is damaged
Bearings on the
motor shaft are worn
Won't turn on
and seized.
Motor is broken
The switch is
always in the on
The switch contacts
position. The
are stuck.
blower cannot be
shut off.
Fault Position
PCBA in the housing
Motor in Ducted
Assembly
Motor in Ducted
Assembly
Switch in the handle
housing
Test & Solution
Test the PCBA according to the procedure in the
diagnosing section, if it is broken, replace the
PCBA.
Use a stick to turn the fan from the air inlet, if
the fan is not able to move, it means the
bearings are stuck. Replace the duct assembly.
Measure the resistance between any two of the
three cables of the motor by using a multimeter.
If the resistance is infinite, replace the motor
and ducted assembly.
Insert a good battery, if the blower will run
regardless of the switch is on or off , replace
the switch assembly in the handle housing.