Vision ZB5311IN-5 Installation & Operation Manual page 2

Glass break detector

Advertisement

Glass Break Detector
Front
Rear
Operation
Notice: If you are installing the entire Z-Wave™ system for the first time,
please refer to the installation guide of Z-Wave™ Interface Controller.
1
For
"Inclusion"
in (adding to) a network:
-
SmartStart:
Please scan the QR Code from glass break detector for
SmartStart. QR code and PIN is located on the device, also there is a
Full DSK string on the enclosed DSK card. Please keep DSK card
carefully for future inclusion needed.
Remark:
a.
Z-Wave SmartStart aims to shift the tasks related to inclusion of an end
device into a Z-Wave network away from the end device itself, and
towards the more user-friendly interface of the gateway.)
b.
The DSK label will on the backside of ZB5311-5, Scan the DSK label
to access the SmartStart if gateway 's UI supports SmartStart.
(Remark: The QR code is for use with Z-Wave SmartStart by using
"DSK," "Device Specific Key," "PIN," or "PIN code," etc.)
Manual:
If your controller does not support SmartStart, you may use
classic inclusion by performing the following stepsPut the Z-Wave™
Interface Controller into "inclusion" mode, and following its instruction to
add the ZB5311-5 to your controller. To get in the "inclusion" mode, press
the Program Switch of ZB5311-5 once for sending the NIF. After sending
NIF, Z-Wave will send the auto inclusion; otherwise, ZB5311-5 will go to
sleep after 30 seconds. After inclusion successfully, the Green LED will
be solid on for 0.5 second.
For "Exclusion" from (removing from) a network: Put the Z-Wave™
2
Interface Controller into "exclusion" mode, and following its instruction to
delete the ZB5311-5 from your controller. Press the Program Switch of
ZB5311-5 once to be excluded, the Green LED will flash 5 times quickly
after successful exclusion.
Note:
All user and network settings will be cleared and the device reset
to factory defaults when the device is excluded.
Trigger Response:
3
When Glass Breaking Sound Detected: The sensor will send Notification
Report (refer to Table 1 & 2 & 3).
10 Seconds after Glass Breaking Sound Detected: The sensor will send
Notification Report (refer to Table 1 & 2 & 3).
When the cover or tamper has been opened or closed: The sensor will
send Notification Report (refer to Table 1 & 2).
4
Wake Up Notification:
Press the program switch once to send NIF, it takes around 5 seconds
to send "Wake Up Notification" for receiving all the command class from
controller. The ZB5311-5 will go to sleep mode without receiving any
Z-Wave command till 10 seconds.
5
Auto Wake Up:
Use "Wake Up" command to set up the awaking time and send the wake
up notification to controller. User can use command to change the auto
wake up from 10 minutes to 1 week, Interval increment is 200 seconds.
(Default Value: 1 hour.)
Battery Capacity Detection:
6
Use "Battery Get" command to have the battery capacity back in %. It
will detect the battery capacity automatically. Low Battery Auto Report
(low battery is set as 2.6+/-0.1 Voltage).
Dip Switch
High Sensitive
ON
1
2
Low Sensitive
ON
ON
ON
1
2
1
2
1
2
or
or
Test Mode Switch
Cover
Switch
Program Switch
Tamper
Switch
Association:
7
* Support two groups with 5 nodes.
* Group 1 = Lifeline (Battery, Notification, Reset Locally)
* Group 2 = Basic Set (Basic Set)
To Enter / Exit Glass Break Detection Testing Mode:
8
Enter Test Mode: Press Test Mode Switch once and the Red/ Green
LED lights up for 1 second to indicate that it has entered the Test Mode.
Exit Test Mode (Automatically): The ZB5311-5 will exit the Test Mode
without listening the low frequency sound till 10 minutes.
Exit Test Mode (Manually): Press Test Mode Switch once during the
Test Mode, Red/Green LED flashes 3 times to indicate that the Test
Mode has been exited.
Glass Break Detection Testing Mode Behavior:
9
Low frequency sound detected: Green LED flashes once.
Glass breaking sound detected: Red LED is solid on for 0.5 second and
the sensor will send Notification Report (refer to Table 1 & 2 & 3).
1 second after glass breaking sound detected: The sensor will
send Notification Report (refer to Table 1 & 2 & 3).
Sensitivity Adjustment:
10
There is a Dip Switch inside of the ZB5311-5 for sensitivity selection.
User could adjust the sensitivity for meeting the environment's situation.
※The Red LED will flash once when adjusting the Dip Switch.
Dip Switch vs. Sensitivity
Switch 2
P.S.: Default – High Sensitivity
11
Support Explorer Frame Function
12
All the rest commands depend on Z-Wave standard
Factory Default Reset:
Long press the program switch up to 10 seconds
13
to send the "Device Reset Locally Notification" command and reset to the
factory default. The Green LED will flash 5 times quickly after finishing the
Factory Default Reset.
(Remark: This is to be used only in the case of primary controller being
inoperable or otherwise unavailable.)
Support OTA Firmware update from controller.
14
controller manual.
Once OTA function success, we recommend you
exclusive the device & inclusive again before use the device.
Support SECURITY S0, SECURITY S2 UNAUTHENTICATED & SECURI-
15
TY S2 AUTHENTICATED.
A Security Enabled Z-Wave Controller must be used to fully utilize the
16
products.
Switch 1
On
On
Low
Off
Low
Please refer to your
Off
Low