Beginning Dynamic Setup; Beginning Dynamic Init - DBM ACE9600 Programmer's Manual

Hide thumbs Also See for ACE9600:
Table of Contents

Advertisement

Advanced Channel Emulator
Received command -
Ack: Dynamic DelayInterval 50
Notes:
 The parameter DelayInterval sets the interval for Delay, Frequency
Offset, Attenuation, Phase Offset, and Noise Density type files.

Beginning Dynamic Setup

Syntax:
Begin Dynamic Setup
Function:
Before changing dynamic run parameters or dynamic data file selections, the
instrument must be placed in the Setup state. Once the state is acknowledged as
Setup, changes in the dynamic run parameters or dynamic data file selections
may begin. See Changing Selected File for Dynamic for more information
about selecting files for dynamic data parameters.
Returns:
Nak:
<error message>
or
Ack:
Dynamic State Setup
Where:
<error message>

Beginning Dynamic Init

Syntax:
Begin Dynamic Init
Function:
After changing dynamic run parameters or selecting files for dynamic data
parameters, the instrument must be placed in the Init state to initialize the
dynamic run to the starting point. Once the initialization procedure finishes and
the state is acknowledged as Ready, the command to Start may be sent. See
Changing Selected File for Dynamic for more information about selecting files
for dynamic data parameters.
Returns:
Nak:
<error message>
or
Ack:
Dynamic State Ready
Where:
<error message>
20
Descriptive text describing cause of error
Descriptive text describing cause of error
dBm
ACE9600
Programmer's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACE9600 and is the answer not in the manual?

Table of Contents