Dip Switch Configuration; Factory Default Communication Parameters; Bulk Erase; Bulk Erase Steps - Honeywell PW7000 Series Installation And Configuration Manual

Osdp reader interface
Table of Contents

Advertisement

2.4 DIP Switch Configuration

The four switches on S1 DIP switch are used to configure the operating mode of the
PW7K1R1E. DIP switches are read on power-up except where noted.
1
OFF
ON
OFF
ON
ON
All other switch settings are unassigned and reserved for future use. X = don't care.

2.5 Factory Default Communication Parameters

Table 3: Factory Default Communication Parameters
Network
Subnet Mask
Default Gateway :192.168.0.1

2.6 Bulk Erase

The bulk erase function can be used for the following purposes:
• Erase all configuration, sets PW7K1R1E to OEM setting (sanitize board).
• Restore to OEM default parameters.
2.7

Bulk Erase Steps

Do not remove power during steps 4-6.
1. Set S1 DIP switches to: 1 & 2 "ON", 3 & 4 "OFF".
2. Apply power to the PW7K1R1E.
3. Watch for LEDs 1 & 2 and 3 & 4 to alternately flash at a 0.5 second rate.
PW7K1R1E OSDP Reader Interface, Configuration, and Installation Guide, Document 800-26498
2
3
4
OFF
OFF
OFF
Normal operating mode.
After initialization, enable default User Name (admin) and
Password (password). The switch is read on the fly, no need
X
OFF
OFF
to reboot. See IT Security section for additional information
ON
OFF
OFF
Use factory default communication parameters.
ON
OFF
OFF
Use OEM default communication parameters. Contact
system manufacture for details. See Bulk Erase below.
ON
OFF
OFF
Bulk Erase prompt mode at power up. See Bulk Erase
section.
: static IP address: 192.168.0.251
: 255.255.0.0
PW7K1R1E Wiring and Setup

DIP Switch Configuration

Definitions
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pw7k1r1e

Table of Contents