4-1. Cooling capacity

¢ Model: ADUH09LUAS1
AFR
°FDB
64
°FWB
54
TC
SHC
IP
°FDB
kBtu/h
kW
14
8.43
6.91
0.23
23
7.99
6.55
0.26
32
7.55
6.18
0.27
41
7.47
5.82
0.27
50
7.67
5.46
0.27
59
7.16
5.28
0.28
67
8.57
6.22
0.45
77
8.11
5.95
0.51
87
7.58
5.83
0.58
95
7.11
5.57
0.64
104
6.04
5.28
0.60
115
5.55
5.24
0.51
AFR
°CDB
17.8
°CWB
12.2
TC
SHC
IP
°CDB
kW
-10.0
2.47
2.02
0.23
-5.0
2.34
1.92
0.26
0.0
2.21
1.81
0.27
5.0
2.19
1.71
0.27
10.0
2.25
1.60
0.27
15.0
2.10
1.55
0.28
19.4
2.51
1.82
0.45
25.0
2.38
1.74
0.51
30.6
2.22
1.71
0.58
35.0
2.08
1.63
0.64
40.0
1.77
1.55
0.60
46.0
1.63
1.54
0.47
4-1. Cooling capacity
CFM
70
75
60
63
TC
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
9.39
6.95
0.23
9.71
7.55
8.90
6.59
0.26
9.21
7.16
8.41
6.22
0.28
8.70
6.76
8.32
5.86
0.28
8.60
6.37
8.54
5.50
0.27
8.83
5.98
7.98
5.31
0.28
8.25
5.78
9.55
6.25
0.46
9.88
6.80
9.03
5.99
0.52
9.34
6.51
8.45
5.87
0.59
8.74
6.38
7.92
5.60
0.65
8.19
6.09
6.73
5.31
0.61
6.96
5.78
6.19
5.27
0.52
6.40
5.73
3
m
/h
21.1
23.9
15.6
17.2
TC
SHC
IP
TC
SHC
kW
kW
2.75
2.04
0.23
2.85
2.21
2.61
1.93
0.26
2.70
2.10
2.47
1.82
0.28
2.55
1.98
2.44
1.72
0.28
2.52
1.87
2.50
1.61
0.27
2.59
1.75
2.34
1.56
0.28
2.42
1.69
2.80
1.83
0.46
2.90
1.99
2.65
1.75
0.52
2.74
1.91
2.48
1.72
0.59
2.56
1.87
2.32
1.64
0.65
2.40
1.79
1.97
1.56
0.61
2.04
1.69
1.81
1.55
0.48
1.88
1.68
353
Indoor temperature
80
67
IP
TC
SHC
IP
kW
kBtu/h
kW
0.23
10.67
8.18
0.23
0.26
10.12
7.76
0.27
0.28
9.56
7.33
0.28
0.28
9.45
6.90
0.28
0.27
9.70
6.48
0.28
0.28
9.06
6.26
0.29
0.46
10.85
7.37
0.47
0.52
10.26
7.05
0.53
0.60
9.60
6.91
0.61
0.65
9.00
6.60
0.66
0.62
7.65
6.26
0.63
0.52
7.03
6.21
0.53
600
Indoor temperature
26.7
19.4
IP
TC
SHC
IP
kW
0.23
3.13
2.40
0.23
0.26
2.97
2.27
0.27
0.28
2.80
2.15
0.28
0.28
2.77
2.02
0.28
0.27
2.84
1.90
0.28
0.28
2.66
1.83
0.29
0.46
3.18
2.16
0.47
0.52
3.01
2.07
0.53
0.60
2.81
2.03
0.61
0.65
2.64
1.93
0.66
0.62
2.24
1.83
0.63
0.48
2.06
1.82
0.49
- 9 -
85
90
71
73
TC
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
11.31
8.15
0.24
11.95
8.68
10.72
7.73
0.27
11.33
8.23
10.13
7.30
0.28
10.70
7.77
10.02
6.87
0.28
10.58
7.32
10.29
6.45
0.28
10.87
6.87
9.61
6.23
0.29
10.15
6.64
11.50
7.34
0.47
12.15
7.82
10.88
7.02
0.53
11.49
7.48
10.18
6.88
0.61
10.75
7.33
9.54
6.57
0.67
10.08
7.00
8.11
6.23
0.63
8.57
6.64
7.45
6.19
0.54
7.87
6.59
29.4
32.2
21.7
22.8
TC
SHC
IP
TC
SHC
kW
kW
3.32
2.39
0.24
3.50
2.55
3.14
2.27
0.27
3.32
2.41
2.97
2.14
0.28
3.14
2.28
2.94
2.01
0.28
3.10
2.15
3.02
1.89
0.28
3.19
2.01
2.82
1.83
0.29
2.98
1.95
3.37
2.15
0.47
3.56
2.29
3.19
2.06
0.53
3.37
2.19
2.98
2.02
0.61
3.15
2.15
2.80
1.93
0.67
2.96
2.05
2.38
1.83
0.63
2.51
1.95
2.18
1.81
0.49
2.31
1.93
4. Capacity table
IP
kW
0.24
0.27
0.29
0.29
0.28
0.29
0.48
0.54
0.62
0.67
0.64
0.54
IP
0.24
0.27
0.29
0.29
0.28
0.29
0.48
0.54
0.62
0.67
0.64
0.50

Advertisement

Table of Contents
loading

Table of Contents