Invacare® NordBed™ Kid en Children`s Bed User Manual This manual MUST be given to the user of the product. BEFORE using this product, this manual MUST be read and saved for future reference.
Page 2
All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.
We are continuously working towards ensuring that the company’s impact on the environment, locally and globally, Invacare reserves the right to alter product specifications is reduced to a minimum. without further notice. We only use REACH compliant materials and components.
Risk of injury or damage instructions, contact a healthcare professional, Improper use of this product may cause injury Invacare provider or qualified technician before or damage. attempting to use this product. – Do not use the bed for the transportation of a –...
– Due to regional differences, refer to your the mattress table in chapter 8 Technical Data, local Invacare catalog or website for available page 20 . accessories or contact your local Invacare –...
Do not dispose of this product in normal This bed can be used together with Invacare household waste approved accessories and medical electrical equipment connected to the heart (intracardially)
Page 8
Invacare® NordBed™ Kid Max XXX cm Min XXX cm Indicates the correct body position in the bed. Definition of min. and max. height of the user (depending on bed size). Max XXX cm Min XXX cm See 3.1 Intended Use, page 9 .
The bed is intended for disabled children with limited 3.3 Accessories mobility, from 3–12 years of age and a body size of – NordBed Kid Small: 75 - 125 cm Due to regional differences, refer to your local – NordBed Kid Medium: 125 - 135 cm Invacare website or catalog for details about available –...
4 Usage Castors might make marks on different types of absorbing floor surfaces - such as untreated or badly treated floors. To prevent marks, Invacare® recommends to place a suitable kind of protection 4.1 General Safety Information between the castors and the floor.
Usage Hand Control Box Height adjustment • Up (p): Raise the bed. • Down (q): Lower the bed. Back section • Up (p): Raise the back section. • Down (q): Lower the back section. Thigh section • Up (p): Raise the tight section. •...
Invacare® NordBed™ Kid 1. Slightly pull and hold the top bar upwards with both WARNING! hands Risk of Falling 2. Push and hold the two latches towards each other. – Never leave the user unattended in the bed 3. Lower the side rail and release the two latched before with the side rail down or open.
Page 13
Usage Opening the doors Pull out the pin, rotate clockwise by 90 degrees and release it to position the tab in the horizontal slot. Push up the knob and lift the latch. While holding up the latch press the corresponding lever on the underside and fold the door.
Invacare® NordBed™ Kid Closing the doors Unfold the door without the latch on the top bar and ensure the locking mechanism on the underside engages Close the folded doors and ensure the locking with an audible click. mechanisms on the underside engage with an audible click.
Usage 1. Lift the leg section up to desired height. CAUTION! 2. Lower it until it stays in a fixed position. Risk of injury – A minimum of two persons is required for Down – from upper position an emergency release of a mattress support section.
– Never use a solvent (cellulose thinner, acetone Contact your Invacare provider or in-house service etc.) that changes the structure of the plastic department for service.
Maintenance In Domestic Care Metal components may also be cleaned with pressurized water, but not high pressure or steam. Method: Follow the application notes for the used disinfectant and wipe-disinfect all accessible surfaces. Wood (including textile straps on side rails, if existing) Disinfectant: Ordinary household disinfectant.
Invacare® NordBed™ Kid handling in each country. Contact your local waste 6 After Use management company for information. 6.1 Disposal 6.2 Reconditioning Be environmentally responsible and recycle this product This product is suitable for reuse. To recondition the product through your recycling facility at its end of life.
Troubleshooting 7 Troubleshooting 7.1 Troubleshooting Symptom Possible cause Remedy Bed section does not move End of stroke reached Operate opposite button Bed not plugged in Plug in mains cable Ensure hand control correctly connected Hand control not connected to control unit. Call dealer / technician to replace hand Hand control defective Full bed: No electric function does work...
Invacare® NordBed™ Kid 8 Technical Data 8.1 Dimensions Bed Dimension [cm] NordBed Kid NordBed Kid NordBed Kid Small Medium Large Mattress support width A Total width B Internal length C Back section length D Seat section length E Thigh section length F...
Technical Data 8.2 Maximum Loads NordBed Kid NordBed Kid NordBed Kid Small Medium Large Max. safe working load (including 100 kg 115 kg 115 kg accessories) Max. user weight (provided that the weight of the mattress and the accessories do...
Invacare® NordBed™ Kid Dimensions of mattress [cm] NordBed Kid NordBed Kid NordBed Kid Small Medium Large Width – for bed without upholstery Width – for bed with upholstery 8.6 Environmental conditions Storage and Transportation Operation Temperature -10°C to +50°C +5°C to +40°C Relative humidity 20% to 90% at 30°C - not condensing...
Electromagnetic compatibility (EMC) 9 Electromagnetic compatibility (EMC) 9.1 General EMC information Medical Electrical Equipment needs to be installed and used according to the EMC information in this manual. This product has been tested and found to comply with EMC limits specified by IEC/EN 60601-1-2 for Class B equipment. Portable and mobile RF communications equipment can affect the operation of this product.
Invacare® NordBed™ Kid Immunity test Electromagnetic environment – guidance Test / Compliance level < 0% U for 0,5 cycle at Voltage dips, short Mains power quality should be that of a typical commercial or hospital 45° steps interruptions and environment. If the user of this product requires continued operation during...
Page 25
Electromagnetic compatibility (EMC) Test Frequency Service Maximum Immunity test Band (MHz) Modulation Distance (m) (MHz) power (W) level (V/m) GSM 1800; CDMA 1900; 1720 Pulse GSM 1900; 1845 1700 - 1990 modulation DECT; LTE Band 1970 217 Hz 1, 3, 4, 25; UMTS Bluetooth, WLAN, 802.11...