Download Print this page

ONNLINE Onnflood CEB976 User Manual page 2

Led floodlight 50w, led floodlight 80w, led floodlight 100w, led floodlight 200w

Advertisement

Available languages
  • EN

Available languages

Operation instruction
Please read the use instructions carefully before use. And please keep this instruction for future reference.
1. Specification:
SAP code
Supply
Voltage
Power
Consumption
Lumen Output
Color
Temperature
CRI
Beam angle
Power Factor
Operating
-35°C <Ta < 50°C
Temp Range
IP Rating
IK Rating
Safety
Classification
Average Lamp
Life
Dimensions(
mm)
Weight
Installation
2. Safety instruction:
Electrical products can cause death or injury damage to property. If in any doubt about the installation or use of this
product, please consult a competent electrician.
1)
Before mounting and maintenance please make sure that the electrical supply has been switched off to avoid
electric shock.
2)
The light must be earthed.
3)
Replace the cracked protection glass immediately and use only original parts to substitute.
4)
Before maintenance work, the power should be switched off. The maintaining should be done only by a
qualified electrician.
3. Installation:
CEB976
100~240V -
50Hz/60Hz
50W
5000lm
4000K
>70
140*70
>0.9
-35°C <Ta < 50°C
65
08
Class I
50,000 Hours
254*84*292
3.3kgs
wall mounted
CEB978
100~240V -
50Hz/60Hz
80W
8000lm
4000K
>70
140*70
>0.9
-35°C <Ta < 50°C
65
08
Class I
50,000 Hours
254*84*292
3.5kgs
wall mounted
CEB977
200~240V -
50Hz/60Hz
100W
10000lm
4000K
>70
140*70
>0.9
-35°C <Ta < 50°C
65
08
Class I
50,000 Hours
277*84*392
4.1kgs
wall mounted
GB
CEB979
200~240V -
50Hz/60Hz
200W
20000lm
4000K
>70
140*70
>0.9
65
08
Class I
50,000 Hours
381*89*395
6.0kgs
wall mounted
2