SainSmart Coreception 3D Printer Trouble Shooting
1. Cura settings (specifically print head size settings and why they are)
There is a known bug for the x-min and the y-min. These settings are used to set the hot
end size for the options to print all at once or island. This is not a concern with the
coreception as the print dimensions takes into account the size of the print head.
·For versions that do not allow the recommended settings use the below:
·x min = 0
·y min = -10
·x max = 10
·y max =10
www.sainsmart.com
support@sainsmart.com
Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Coreception and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SainSmart Coreception

  • Page 1 ·For versions that do not allow the recommended settings use the below: ·x min = 0 ·y min = -10 ·x max = 10 ·y max =10 www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 2 ) MKS provides multiple flavors of firmware for the MKS robin nano 1.2 board that is used in www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 3 ·If all connections are in place and not broken wires are observed it may be a component failure. Image via 3dwork.io www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 4 To the selected location of the remote extruder. The new cable should connect to the Motor e0 pictured below. ·Example T-slot nut assortment from amazon. Click here. www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 5 14. Jerking or no movement on 1 or more axis or Z lead screws. ·This is typically a failure of the stepper driver or a disconnected motor cable. www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 6 In any case, please reach out to SainSmart support via support@sainsmart.com. www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 7 Issue command G503 Locate the M92 E##. Should be 381.5 on the coreception if you have never changed it.
  • Page 8 --default #Type of heat manager for this heatedBed. >PIDTEMPBED # 1:PID ; 0:bang-bang >DEFAULT_bedKp 10.00 --default >DEFAULT_bedKi 0.023 --default >DEFAULT_bedKd 305.4 --default www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 9 >DEFAULT_bedKd 155.200 # --default By default on the coreception heatbed is set for bang mode. If you want to change it I would run the same as you do for the extruder. Just set a lower temp (max of 100) and we have to specify the bed.
  • Page 10 Run the bed autotune: M303 E-1 S60 C8 Set the PID for the bed: M304 P118.480 I22.610 D155.200 To save: M500 To verify use M503. www.sainsmart.com support@sainsmart.com Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.
  • Page 11 Property of SainSmart.com. Unlawful to copy or reproduce in any manner without the express written consent.