Use Wall Receptacle
Standard 208/230V, 3-wire grounding
receptacle rated 15A
Standard 208/230V, 3-wire grounding
receptacle rated 20A
Standard 208/230V, 3-wire grounding re-
ceptacle rated 30A
!
WARNING
• This appliance should be installed in accordance with the National Electrical Code.
• Use of extension cords could cause serious injury or death.
- Do not use an extension cord with this air conditioner.
- Do not use surge protectors or multi-outlet adapters with this air conditioner.
• Never push the TEST button during operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this plug. If this device trips, the cause should be corrected
before further use.
!
CAUTION
• The conductors inside this cord are surrounded by shields, which monitor leakage current.
These shields are not grounded. Periodically examine the cord for any damage. Do not use
this product in the event the shields become exposed.
Avoid shock hazard. This unit cannot be user-serviced. Do not open the tamper resistant
sealed portion. All warranties and performance will be voided. This unit is not intended to be
used as an ON/OFF unit.
NOTICE
DO NOT USE AN EXTENSION CORD on 208/230 Volt units.
All wiring should be made in accordance with local electrical codes and regulations.
Aluminum house wiring may pose special problems. Consult a qualified electrician.
Power Supply
Use 15 AMP. time delay fuse or 15 AMP.
Circuit breaker.
Use 20 AMP. time delay fuse or 20 AMP.
Circuit breaker.
Use 30 AMP. time delay fuse or 30 AMP.
Circuit breaker.
INSTALLATION
Applied Model
LP073IHP.AK3GEUS
(Y4NV07ANLK0.AK3GEUS),
LP093IHP.AK3GEUS
(Y4NV09ANLK0.AK3GEUS),
LP123IHP.AK3GEUS
(Y4NV12ANLK0.AK3GEUS),
LP153IHP.AK3GEUS
(Y4NV15ANLK0.AK3GEUS)