x For outdoor installation, protect from direct sunlight and driving rain.
x Assembly only on a level surface! The housing must not be braced, oth-
erwise water may penetrate.
x The ambient temperature must not be lower than -20°C and not higher
than +50°C.
x The air humidity must be within 30 - 90 % RH.
x
Electromagnetic fields at the installation site must be reliably shielded.
The fixing holes are located in the chambers of the cover screws.
The internal temperature measurement is designed for vertical mounting,
whereby the cables must be led out downwards and sealed with the enclosed
cable glands in order to prevent moisture from penetrating.
After completion of installation, the expert / competent person must issue an
EC Declaration of Conformity for the gate system (complete machine consisting
of gate and drive) in accordance with the area of application and affix the CE
mark and a type plate.