7

Operation

Wear safety gloves!
Wear protective clothing!
DANGER!
Danger of electrocution!
Contact with live components may cause mortal
danger.
CAUTION!
Crushing!
Incorrect work on the Dehumidifier can cause injury
to fingers and hands.
Never put your fingers in the protective grille!
ATTENTION!
- The device is not explosion proof and is not inten-
ded for use in potentially explosive atmospheres.
- The device must not be operated outdoors in the
rain.
ATTENTION!
Children must be supervised and not allowed to play
with the device!
ATTENTION!
Observe mains voltage: The voltage of the power
source must correspond to the information given on
the rating plate (Fig. 2).

7.1 Connection water drain

The water pump is connected to a plastic drain hose
(connection to the unit: 7, Fig. 4, and Fig. 7). The hose is
located on the back of the device (Fig. 7). Unwind the
entire hose, making sure there are no kinks or restric-
tions. Place the end of the tubing in a receptacle (Fig. 6)
or outside.
Make sure that water that flows outside does not pose a
risk of slipping.
LEF-Series | Version 1.02
Fig. 6: Water outlet on the dehumidifier
NOTE!
The position of the sewer should not be too long or
too high (<4.5 m). Otherwise, water may remain in the
pump and lead to leaks.
Connection water pipe
Fig. 7: Connection for water drainage

7.2 Put the dehumidifier into operation

Step 1: Install the unit at the desired location, attach the
drain hose to the connector on the back of the
unit, and place the other end of the tubing in a
receptacle or outside.
Step 2: Plug the power cord into a wall outlet.
Step 3: Press the ON / OFF button on the control panel.
The device automatically switches to operating
mode. Use the arrow keys to set the desired
humidity in the room
Step 4: After using the dehumidifier, press the ON / OFF
button to turn the unit off. The water pump au-
tomatically runs for 10 seconds to drain the
remaining water. After 10 seconds, the pump
automatically turns off.
ATTENTION!
Do not switch the device off by unplugging the
mains plug from the mains socket.
To prevent water from leaking, do not move the
dehumidifier for at least 3 minutes after turning it off.
Operation