You have made a good choice by purchasing and regulations, the state of the art as well as our many UNICRAFT Dehumidifier. years of knowledge and experience. Read the operating manual thoroughly before commissioning In the following cases, the manufacturer assumes no lia- the machine.
Safety CAUTION! Safety boots This combination of symbol and signal words indica- The safety shoes protect the feet against bruising, tes a possibly dangerous situation which may lead falling parts and slipping on slippery surfaces. to minor or light injuries if they are not avoided Protective clothing ATTENTION! Protective clothing is tight-fitting work clothing, with...
Intended use Intended use - Never use the power cord to move or lift the dehumidifier. - Disruptions that affect safety are eliminated immedia- The dehumidifier is only suitable for use in the house, for tely. drying damp walls, for water damage or to reduce the - Do not switch on the device in case of malfunction or if humidity in enclosed spaces.
Due to the constant circulation of the room air through the device, the relative humidity of the air is gradually reduced, whereby a quick and gentle drying of the room is achieved. Fig. 2: Type plate LEF 50 S LEF-Series | Version 1.02...
Emptying key P Press the P button to remove water from the pump res- Fig. 4: Device description LEF 50 S ervoir. During normal operation, the pump automatically deflates as soon as the container is full. Use the P button 1 Foldable strap before moving the device to prevent leakage of water.
Transport, Packaging, Storage Transport, Packaging, Storage Key lock function If the T and P buttons are pressed simultaneously for 2 6.1 Transport seconds, the defrost lamp lights up in the display and all buttons on the control panel are locked. Pressing T and Check the Dehumidifier for visible transport damage af- P again unlocks all keys.
Operation Operation Wear safety gloves! Wear protective clothing! DANGER! Fig. 6: Water outlet on the dehumidifier Danger of electrocution! Contact with live components may cause mortal danger. NOTE! The position of the sewer should not be too long or CAUTION! too high (<4.5 m).
Care, Maintenance and Repair Care, Maintenance and Repair Light pollution Use a vacuum cleaner or tap the filter lightly. The dehumidifier should always be kept in a clean condition. Heavy contamination Carefully wash the filter with lukewarm soapy water (max ATTENTION! 40 °...
Possible errors and solutions 8.3 Maintenance and Repair Maintenance of the water pump The pump is equipped with a quick connection con- ATTENTION! struction. When maintenance is required, the conden- sate hose, float switch ports, and power cord to the pump can be easily disconnected.
The type plate is mounted on the device. company can be used for the treatment. Example 12 Spare parts The Pump for the Dehumidifier LEF 50 S must be orde- red. The Pump has the number 41 in the spare parts DANGER! drawing.
Spare parts 12.2 Spare parts drawing Dehumidifier The following drawing should help you to identify necessary spare parts in case of service. If necessary, send a copy of the parts drawing with the marked components to your authorized dealer. Fig. 12: Spare parts drawing LEF 50S,70S and 90S LEF-Series | Version 1.02...
Electric circuit diagram 13 Electric circuit diagram Fig. 13: Electric circuit diagram LEF 50S Fig. 14: Electric circuit diagram LEF 70 S and 90 S LEF-Series | Version 1.02...
Dr.-Robert-Pfleger-Str. 26 D-96103 Hallstadt herewith declares that the following product Unicraft® Werkstatttechnik Product group: Dehumidifier Type of machine: LEF 50 S, LEF 70 S, LEF 90 S Designation of the machine: 6262050, 6262070, 6262090 Item number: ______________________ Serial number: 20_____...