Maintenance And Repair; Possible Errors And Solutions - unicraft LEF 50 S Operating Instructions Manual

Table of Contents

Advertisement

8.3 Maintenance and Repair

ATTENTION!
- Maintenance and repair work may only be carried
out by qualified personnel.
- Only use original spare parts in case of repair.
- After servicing / repair, all safety devices must be
returned to the unit before it can be put into ser-
vice.
If the dehumidifier does not work properly, contact a
dealer or our customer service. The contact details can
be found in chapter 1.2 Customer Service. All protective
and safety equipment must be reinstalled immediately
after repair and maintenance work has been completed.
9

Possible errors and solutions

Disorder
Engine does not start
Device condenses little or no water
Device switches off during conti-
nuous operation with drain hose
LEF-Series | Version 1.02
Maintenance of the water pump
The pump is equipped with a quick connection con-
struction. When maintenance is required, the conden-
sate hose, float switch ports, and power cord to the
pump can be easily disconnected. The pump can be re-
moved from the container using a flat screwdriver. The
dehumidifier is equipped with an integrated condensate
pump, which pumps the condensate from the dehumidi-
fier into the desired drain. This pump requires routine
maintenance.
Fig. 11: Water pump
Cause
1. Mains voltage is missing
2. Connection cable defective
3. Water collecting container full
4. Room humidity lower than set
1. Room temperature or humidity are
not within the working range
2. Air filter dirty
3. Air supply or exhaust air blocked
4. Device heavily soiled from inside
or cold circuit defective
5. Doors and / or windows open
1. Drain hose kinked or rolled or not
enough slope
2. Water in the tube freezes
Possible errors and solutions
Solution
1. Check fuse
2. Have checked (electrician)
3. Empty the water collector
4. Check set air humidity value, if
necessary set other value
1. Check room temperature (5 ° C to
32 ° C). Check humidity level (at
least 30% RH) Check set air
humidity value, if necessary set
other value
2. Clean the air filter
3. Check, reposition the device
(minimum distance (10 cm) to the
wall
4. Contact customer service
5. Close doors and / or windows
1. Lay the drain hose differently so
that the water can drain away
unhindered
2. Make arrangements that prevent a
freezing of the water
11