Hazardous Location Medium Intensity Power Supply Manual
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Refer to product labelling for applicable
installation locations
DO NOT let any supply cords touch hot
surfaces higher than cord or fixture ratings.
DO NOT mount near gas or electric heaters
Equipment should be mounted in locations
and at heights where it will not be subjected to
tampering by unauthorized personnel.
The use of accessory equipment not
recommended by the manufacturer may cause
unsafe conditions.
DO NOT use this equipment for other than
intended use.
Pictures of the install are required for
warranty purposes
SAVE THESE INSTRUCTIONS!!
Introduction
This manual is for orientation and function of the Power Supply only. Individual manuals
are supplied for each component of Dialight's Safesite® Medium Intensity L864/L865
Dual Strobe System.
NOTE: For Controller connections and wiring refer to its manual.
NOTE: For Flash Head connections refer to its manual.
NOTE: For Photocell connections refer to its manual.
Included in this manual
WARNINGS
Classifications for use
System overview
Installation Tips and requirements
System Installation Requirements for EMC and Lightning Immunity
Power Supply Specifications & Electrical Parameters
Mechanical Dimensions of Power Supply Enclosure
Replacement Part Numbers
Dialight Corporation 1501 Route 34 South
Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com
Page 1 of 21
9100-127-2044-99 Rev C
Release Date: August 2020
The operation and maintenance must be carried
out by authorized personnel.
Repairs and Installation must only be carried
out by a qualified electrician.
Only genuine Dialight replacement parts must
be used when unforeseen repairs are required.
Observe the national safety rules and
regulations during installation!
Earth Grounding is required throughout the
install process. Failure to do so could void all
warranties!
No alterations are allowed without the
agreement from Dialight Corp. Alterations other
than written in this manual will void all
warranties.
Ensure that all conduit or external cable feeds
have been installed so water or condensation
cannot enter the enclosures.
Farmingdale NJ 07727
Document No.

Advertisement

Table of Contents
loading

Summary of Contents for Dialight SafeSite DHZCPSD4C8

  • Page 1 Introduction This manual is for orientation and function of the Power Supply only. Individual manuals are supplied for each component of Dialight’s Safesite® Medium Intensity L864/L865 Dual Strobe System. NOTE: For Controller connections and wiring refer to its manual.
  • Page 2 Warning To avoid electric shock: Be certain electrical power is OFF before and during installation and maintenance. • The Power Supply must only be connected to Dialight Corp approved products. • Warning To avoid explosion: Do not connect to equipment that the Controller is not intended for.
  • Page 3 The technical data indicated on the product label is to be observed. Changes to the design and modifications of the Controller are not permitted. • • Only genuine Dialight replacement parts are to be used when unforeseen maintenance is required. Consult factory at www.Dialight.com or authorized representative as required.
  • Page 4: System Overview

    Document No. 9100-127-2044-99 Rev C Release Date: August 2020 System Overview Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 4 of 21...
  • Page 5 Minimum of 300V rating (if 277Vac is used then a 600V cable is required) UL, CSA and RoHS complaint Flame retardant Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 5 of 21...
  • Page 6 NOTE: Liquid tight, Conduit and TECK (armored) cable are acceptable to be used in the installation, with properly sized conductors. Power Supply Connections Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 6 of 21...
  • Page 7: Power Supply Connections

    AC or DC Input and, if 3/4 NPT needed, output* A conduit “T” can be used at entry 3, for additional mains output or input Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 7 of 21...
  • Page 8: System Block Diagram

    AC or DC Control Power In Signal Multi-way connection cable (up to 550ft) See pg. 4 for conductor sizing SYSTEM BLOCK DIAGRAM Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 8 of 21...
  • Page 9: Dc Terminal Block

    Boards are Labeled Description Color Code Label “A” Communications “A” Gray or White Common Common for RS485 Yellow Label “B” Communications “B” Blue Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 9 of 21...
  • Page 10 Option 1 above is applicable with RS-485 communication cable as purchased from Dialight, part number CAB---183BFD. Where --- represents the cable length in feet. Option 2: When 2 Conductors, a drain wire and either a shield or braid is used.
  • Page 11 Replacement plates will typically have SW1 set to 0; the switch must be set by the installer to match the address that is being replaced. SW1 Position MIOL No. Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 11 of 21...
  • Page 12 Pin 1 or RED in the flash head must go to Pin1 RED in the power supply and so NOTE: The installer should provide this information to the site manager upon completion for future reference when required Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com...
  • Page 13 ORG (Pin 6) = + (positive) for White L865 BRN (Pin 7) = - (return) for White L865 YEL (Pin 8) = - (return) for White L865 Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com...
  • Page 14 WHITE (Pin 4) = + (POSITIVE) for White L865 WARNING: Take care to connect correctly, as incorrect operation can cause damage to the driver modules. Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com...
  • Page 15 There are NO additional fault connections required in the Power Supply enclosure. All faults are sent to the Base controller via the RS485 communications. NOTE: It is vitally important that the RS485 connections are checked and secured. Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com...
  • Page 16: Safety Warning

    9100-127-2044-99 Rev C Release Date: August 2020 Configuration Option Switches NOTE: In previous versions of the Dialight D1RW there were settings required for the dip switches on the micro board. This version only requires position 1 of SW1 to be used.
  • Page 17 NOTE: If these are not blinking then there are no Communications. NOTE: SW1 must be to set to position 0 when used as an AOL Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com...
  • Page 18 Once communication has begun LED’s labeled TX_EN, TX1 and RX1 will begin to flash. LED marked “watchdog” will also blink approx. every half second. STAT1 LED will be solidly lit. Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 18 of 21...
  • Page 19 Document No. 9100-127-2044-99 Rev C Release Date: August 2020 Translator Indicators Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 19 of 21...
  • Page 20 Document No. 9100-127-2044-99 Rev C Release Date: August 2020 Mechanical Dimensions of Power Supply Enclosure: Enclosure dimensions Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 20 of 21...
  • Page 21: Replacement Part Numbers

    9100-127-2044-99 Rev C Release Date: August 2020 Replacement Part Numbers: Exploded view REVISION HISTORY ECO No. DATE 14911 12-11-13 40142 1/9/17 71912 8-7-20 Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com Page 21 of 21...

Table of Contents