To turn on the machine
Making sure that the solution switch on the remote control is on the "OFF" position. Press the start button (one
resonator at a time) and keep it pressed for 5 seconds after you hear combustion starting (sounds like a small
explosion). It is necessary to keep the machine on for about 10 seconds to warm up before turning on the solution
switch. TIP: If the machine fails to start, press the button "KNOCKING" so pressure in the fuel tank can be re-
established. Press the start button again and repeat the above procedure until it starts.
To start fogging
Once the machine has heated up for 10 seconds, flick the solution switch to the ON position. When you are ready to
start fogging, turn clockwise the Chemical Flow Regulator (FIG 1.12). Note: This valve also regulates the amount of
flow/chemical being used, by turning it left to right.
To turn off the machine
Flick the solution switch to the OFF position and press the STOP button. Turn the Chemical Flow Regulator anti-
clockwise to stop the flow of chemical. Tip: After use, keep the machine in operation for 5 seconds to help get rid-off
any chemical mixture still in the system.
MAINTENANCE
Cleaning the Chemical Tank and Pipes
Fill the chemical tank with 25% of clean water and turn on the unit. This will prevent corrosion and the accumulation
of chemical deposits in the tank and pipes.
Spark Plug Maintenance
Remove the spark plug using a spanner or spark plug remover. Remove any carbon deposits between the electrode
and the earth section with a wire brush. Make sure that there is a space of 3 to 5 mm between the electrode and the