Using Your Bag Pasteurizer; Pasteurize; Repeat Last - Dairy Tech Perfect Udder Owner's Manual

Bag pasteurizer/ bag warmer
Table of Contents

Advertisement

USING YOUR BAG PASTEURIZER

Warning: Bags can cause severe burns if
handled before the product is completely
cooled. Always finish the cooling cycle
before handling the bag. Do not handle the colostrum
unless it has cooled.

PASTEURIZE

When "PASTEURIZE" is selected, four profile options will
appear. These options dictate what will occur when
pasteurization is complete.

1. REPEAT LAST

2. FEED NOW
3. TO STORE
00/00/00
XX.XX °F
PASTEURIZE
Repeat
Feed Now
Last
revJUNE2016
Selecting the "REPEAT LAST" Pasteurization Option will open
a screen that shows the parameters of the last Pasteurization
Option ran.
You have 3 choices: BACK, ADJUST or START
1.
3 options
18:00
2.
PROGRAM SETTINGS" instructions listed in the FEED
LATER Pasteurize Options section.
3.
To Store
program.
Once the program is in progress, the screen will indicate
which stage the program is in.
Upon completion, the Controller Screen will indicate
"COMPLETE".
Perfect Udder® Bag PASTEURIZER/WARMER Owner Manual
REPEAT LAST
This example shows a "Pasteurize, To Store" Option.
00/00/00
XX.XX °F
PASTEURIZE TO STORE
PASTEURIZE TEMPERATURE
DWELL TIME
COOL TEMPERATURE
START
Press "BACK" button and return to the
"Pasteurize" menu to select from one of the other
Press "ADJUST" to change the current
ADJUST
settings. Please refer to the "ADJUST
START
When you are satisfied with your
adjustments, press "START" to begin the
Pressing the "HOME" button will take the operator
back to HOME screen.
18:00
140.0 °F
110.0°F
60:00:00 H:M:S
75.0 °F
75.0°F
ADJUST
17

Advertisement

Table of Contents
loading

Table of Contents