Voice Messages; Sms Text - Abus Profiline AZ6450 Installation And Operating Instructions Manual

Gsm-interface
Table of Contents

Advertisement

Available languages
  • EN

Available languages

8.4.1

Voice messages

Using the AZ6451 voice module, 4 individual voice texts (at 10 seconds each) can
be recorded and sent to defined contacts in the event of an alarm.
8.4.2

SMS text

The device can send predefined messages to contacts.
IMPORTANT:
The text messages (SMS) for triggering the inputs can be defined individually. The
text messages (SMS) specified below show the default texts only!
Event
Description
Trigger
A message is transmitted if an
Input 1-4
input is triggered.
Reset
A message is transmitted if an
Input 1-4
input trigger is reset.
Tamper
A message is transmitted if the
cover or wall contact is triggered.
Reset
A message is transmitted if the
Tamper
tamper state is is reset.
Fault
A message is transmitted if the
PSTN
analogue telephone line fails.
The message is transmitted
following timeout of the period
set for "PSTN Loss Delay".
Reset
A message is sent when the
PSTN
analogue telephone line is
working again.
Reset
A message is sent when the
GSM
GSM network is stable again.
Fault
A message is sent if the mains
Mains supply
power supply fails. The message
voltage
is transmitted following timeout of
the period set for "AC Loss
Delay".
Reset
A message is sent when the
Mains supply
mains power supply is resumed.
voltage
Battery fault
A message is sent if the battery
is missing or of the voltage falls
below 11 V DC.
Text message (SMS)
Input 1: "Intruder Alarm"
Input 2: "Panic Alarm"
Input 3: "Fire Alarm"
Input 4: "Emergency Alarm"
Input 1: "Intruder Restore"
Input 2: "Panic Restore"
Input 3: "Fire Restore"
Input 4: "Emergency Restore"
"GSM box tamper"
"GSM box tamper OK"
"Line fault"
" Phone Line OK"
"GSM line OK"
"Mains loss"
"Mains power OK"
"GSM low battery"