Available languages

Capacitance
7
Range
60.00 nF
600.0 nF
6.000 μF
60.00 μF
600.0 μF
6.000 mF
60.00 mF
Overload protection 1000 V
Diode test
8
Test voltage
approx. 3.3 V
Overload protection: 1000 V
Acoustic continuity check
9
Test voltage
approx. 1.2 V
Overload protection: 1000 V, Measuring range max. 600 Ω; <10 Ω continuous tone
NCV Non-contact AC voltage test
10
Test voltage
>100 - 750 V/AC
Frequency: 45 - 400 Hz
Never exceed the maximum permissible input values. Do not touch any circuitry
or connection points when voltages exceeding 33 V/ACrms or 70 V/DC might be
applied. Risk of fatal injury!
Accuracy
±(4% + 20)
±(8.0% + 20)
Not specified
Resolution
0.001 V
Resolution
0.1 Ω
Distance
max. 10 mm
Resolution
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
0.001 mF
0.01 mF