Understanding Your Energizer - Gallagher M950 Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Gallagher 3E4449 M950 M1400 Energizer User Manual

UNDERSTANDING YOUR ENERGIZER

Power Supply
230 Vac. Internal protec on against
poor power supplies
HANDY HINT
Find a loca on for your ground system that is permanently
damp, has high fer lity or salinity and is away from dairy
sheds. Install the ground system at least 10m (33 ) from any
power supply ground peg, underground telephone or power
cable. The best construc on is 2m (6 ) long galvanised stakes
G879 or Super Ground Kits G880, 3m (10 ) apart, connected
to the energizer by high quality Lead-out cable G627. Do not
use materials that rust.
(Use G6272 if the ground system is over 100m (300 )
from the energizer).
LED Indicators
Indicates fence performance
with each pulse
Earth Terminal
Connects to the
earth system
LED
Green
Green
Yellow
Yellow
Red
Fence Terminal
Connects to the fence
wires
G876
G879
Voltage
> 7.5 kV
> 6 kV
> 4.5 kV
> 3 kV
> 0 kV
9