COMPOSITION OF THERMAL INSULATION
The thermal insulation is made from expanded polyurethane 40 kg/m
5. START-UP
FIRST CLEANNING
Clean the unit before connecting to the electricity supply.
INSPECTION
Check that the voltage and power line frequency coincide with those indicated on the specification plate of the appliance.
The unit should not be used in threatening atmospheric or fire risk conditions.
Check that there are no defects on the unit resulting from its transportation. The manufacturer will not be liable for damage
suffered during transportation or arising from incorrect storage.
Check the operation of the moving components of the unit.
Check the safety of the control board, electrical cables and connections.
Check that all the interior and additional accessories are present.
GENERAL CONNECTIONS
Be sure the power cable is not damaged.
If the power cable is damaged it must be replaced by another type H05-VV-F or H05-VVH2-F. This repair must be
performed by qualified personnel.
It is essential that the electrical installation to which the unit is going to be connected has an EARTH LEAD, as well as the
necessary thermal and differential magnetic protection.
The power supply must have the suitable section for the consumption of the appliance.
If various units are installed in a row, each one must be connected independently to the power supply, avoiding the use of
extension leads or multiple plugs.
The manufacture disclaims all liability in the event that any of the above points are not followed.
OPERATING ELEMENTS AND INDICATORS
COMPRESSOR
THERMOSTAT
FAN
TURN ON/ OFF
Press
until appear
To turn off the computer press the button for 5 sec until appear
Check set point
"set" 1 sec and the set point or set point will appear. Release key.
Press
Up the set point
GÉNÉRAL SWITCH
ON
to turn on the unit.
OFF
3
, with expansive agent C4H5F5.
 One the inside of the unit is clean, connect the power supply and
place the switch in the
up.The thermostat display shows the air temperature inside the
unit.
 Three minutes after turning on the switch, the LED showing the
compressor is working will light up permanently.
 The initial temperature that is shown on the thermostat display
will be the ambient temperature. As the machine works, the
temperature will reduce until it reaches its operating temperature.
and the condensing unit will stop working.
I/ON
position. The switch should be lit
17