Advertisement

Quick Links

EN
USE AND MAINTENANCE MANUAL
ATEX marking:
INTRODUCTION ......................................................................................................................................................... 2
PURPOSE ................................................................................................................................................................... 2
RESERVATIONS OF MANUFACTURER .................................................................................................................. 3
TECHNICAL DATA ..................................................................................................................................................... 3
STRUCTURE ADN FUNCTION ................................................................................................................................. 4
ASSEMBLY AND STARTUP ..................................................................................................................................... 5
OPERATIONAL USE .................................................................................................................................................. 8
TROUBLESHOOTING GUIDE .................................................................................................................................. 14
MAINTENANCE AND REPAIR ................................................................................................................................ 14
OCCUPATIONAL HEALTH AND SAFETY .............................................................................................................. 15
TRANSPORT AND STORAGE ............................................................................................................................... 15
TERMS OF WARRANTY ......................................................................................................................................... 16
DECLARATION OF CONFORMITY ........................................................................................................................ 16
Producer: KLIMAWENT S.A.
81-571 Gdynia, ul. Chwaszczyńska 194
tel. 58 629 64 80, 58 771 43 40
fax 58 629 64 19
email:
klimawent@klimawent.com.pl
www.klimawent.com.pl
Filtering unit BIG-12000/Ex
II 3 D Ex tD A22 T200ºC
Contents:
(KOMPAC AIR 325 4x4 12000)
October 2019
issue:

Advertisement

Table of Contents
loading

Summary of Contents for Klimawent BIG-12000/Ex

  • Page 1: Table Of Contents

    USE AND MAINTENANCE MANUAL Filtering unit BIG-12000/Ex (KOMPAC AIR 325 4x4 12000) II 3 D Ex tD A22 T200ºC ATEX marking: Contents: INTRODUCTION ................................. 2 PURPOSE ................................... 2 RESERVATIONS OF MANUFACTURER ........................3 TECHNICAL DATA ..............................3 STRUCTURE ADN FUNCTION ..........................4 ASSEMBLY AND STARTUP .............................
  • Page 2: Introduction

    Construction of BIG-12000/Ex meets the requirements of the current state of technology as well as the safety and health assurances included in: the safety and health assurances included in: 2006/42/EC Directive of the European Parliament and of the Council of the 17 May, 2006 on machinery, amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24);...
  • Page 3: Reservations Of Manufacturer

    Klimawent – the warranty of highest quality at attractive price BIG-12000-Ex filtering unit can be installed, exclusively in areas classified as 22, or in areas not featuring explosive hazard. According to the ATEX 137 Directive, User has to determine the environment where the appliance shall be used.
  • Page 4: Structure Adn Function

    CAUTION: The switchgear is delivered upon separate order. 5.2 Function BIG-12000/Ex filtering unit provides separation of the air containing dry dust fraction. The dust laden air is guided to the chamber of filters. Here, in the decompression process and because of the flow velocity reduction, larger particles of dust are extracted into the hopper chamber, and subsequently they fall into the waste container.
  • Page 5: Assembly And Startup

    Klimawent – the warranty of highest quality at attractive price Precise dust cleaning proceeds while the air flows through the cartridge filters. In the Fig. No.3 is presented a run diagram of the air flow through the filtering unit. As the dust accumulates on the operational surface of the cartridge filters, this reduces the air flow intensity.
  • Page 6 Klimawent – the warranty of highest quality at attractive price 6.3 ATEX Directive BIG-12000/Ex filtering unit has been classified, according to the 2014/34/Ex Directive and therefore, it is important to take precaution measures during the installing and start-up, and follow subsequent aspects: ...
  • Page 7 Klimawent – the warranty of highest quality at attractive price Fig. No.6 – Connection Diagram 1/3 Fig. No.7 – Connection Diagram 2/3 Fig. No.8 – Connection Diagram 3/3 10.10.2019 Filtering unit BIG-12000/Ex 7 z 16...
  • Page 8: Operational Use

    Klimawent – the warranty of highest quality at attractive price OPERATIONAL USE The filtering unit is designed for filtration of the air, at the workplaces, according to the purpose of application as described in Section 2 of the present Use and Maintenance Manual.
  • Page 9 Klimawent – the warranty of highest quality at attractive price Micro-controller A2 provides control of the electromagnetic valves – the function is described in Section 7.2. Supply 230V ±10%; 50Hz ±1%; L; N; PE Fig. No.13 – Decompression panels The A3 terminal box connects the cable to the sensors on the venting panel, with the output cable, (going out of the Switchgear A1).
  • Page 10 Klimawent – the warranty of highest quality at attractive price Filtering unit BIG-12000/Ex 10 z 16 10.10.2019...
  • Page 11 Klimawent – the warranty of highest quality at attractive price 10.10.2019 Filtering unit BIG-12000/Ex 11 z 16...
  • Page 12 Klimawent – the warranty of highest quality at attractive price Filtering unit BIG-12000/Ex 12 z 16 10.10.2019...
  • Page 13 Klimawent – the warranty of highest quality at attractive price 7.3 Startup of the system  Switch on motor switches Q1M, Q2M and the protections in the switchgear A1.  Check if the F1 fuse in the micro-controller is not damaged.
  • Page 14: Troubleshooting Guide

    Klimawent – the warranty of highest quality at attractive price  In the course of operational use, be careful that no ignition sources (e.g. sparks, cigarette butts, embers) gets into the device.  During the emptying of the waste container and during any other activity near the filtering unit, it is important to wear antistatic clothes.
  • Page 15: Occupational Health And Safety

    The second assembly is the self- discharging hopper with the supporting structure. BIG-12000/Ex filtering unit is transported in two assemblies, wrapped in foil, placed on transport pallets. During the time of transport, the assemblies must be located vertically and protected from overturn (being knocked down) and from displacement.
  • Page 16: Terms Of Warranty

    Klimawent – the warranty of highest quality at attractive price TERMS OF WARRANTY The period of warranty for the purchased device indicated in the Card Warranty. The warranty does not comprise: ● mechanical damage and malfunctions caused by User, ●...