Klimawent BIG-2000-N Use And Maintenance Manual

Filtering unit

Advertisement

Quick Links

1
Use and Maintenance Manual
BIG-2000-N
Filtering unit
26.06.2019
Filtering unit BIG-2000-N

Advertisement

Table of Contents
loading

Summary of Contents for Klimawent BIG-2000-N

  • Page 1 Use and Maintenance Manual BIG-2000-N Filtering unit 26.06.2019 Filtering unit BIG-2000-N...
  • Page 2: Table Of Contents

    Assembly and Start-up ................ 7 Operational Use .................. 9 Troubleshooting Guide ................ 13 Maintenance ..................13 Occupational Health and Safety ............14 Transport and Storage ................ 14 Terms of warranty ................14 Sample of the Declaration of Conformity ..........17 Filtering unit BIG-2000-N 26.06.2019...
  • Page 3: Introductory Remarks

    The construction of the BIG-2000-N filtering unit meets the requirements of the current state of technology as well as the safety and health assurances included in: ...
  • Page 4: Application

    2. Application BIG-2000-N filtering unit is appropriate for cleaning the air contaminated with dust- and gaseous impurities, arising during various manufacturing processes. It is perfect in removal of dry dust and fumes emitted during welding, gaseous metal cutting and during other processes, in chemical industry, food processing , pharmaceutics, plastic processing .
  • Page 5: Structure And Function

    Carbon spunbond constitutes replaceable WFCR-BIG-2000 element of the filter. 5. Structure and Function BIG-2000-N filtering unit consists of: – steel sheet housing, – radial fan, – spark catcher, – cut-off dampers – to cut off the air flow while the fan is switched off, –...
  • Page 6 Additionally, the device is equipped with a spark catcher, to avoid entering the welding sparks being drawn into the extraction arm during the welding process. BIG-2000-N filtering unit is fitted with cut-off dampers closing the air inlets for the time when the fan is switched off. This enables additional final filter shaking (cleaning).
  • Page 7: Assembly And Start-Up

    6. Assembly and Start-up The structure of BIG-2000-N filtering unit is adapted for attachment of ERGO LUX extraction arms of workrange 2, 3 or 4 metres and diameter 160 mm. Prior to the operational use, connect the device to the external compressed air installation of pressure 6 –...
  • Page 8 Fig. No.2 – Connection diagram – filtering unit BIG-2000-N Filtering unit BIG-2000-N 26.06.2019...
  • Page 9: Operational Use

    4. The device is equipped with a five-metres-long power supply cable with a plug. To connect the device to the power supply, simply insert the plug into the socket. 7. Operational Use Connection diagram of the appliance is illustrated in Fig. No.2. Fig. No.3 – Control unit BIG-2000-N – front cover 26.06.2019 Filtering unit BIG-2000-N...
  • Page 10 Fig. No.4 – Control unit BIG-2000-N – inside START-UP OF THE APPLIANCE: 1. Open the compressed air valve. 2. Insert the plug into the power supply socket. 3. Switch on the motor switch Q1M. 4. Switch on the power supply by setting the S1 into position “ON” ; this will be indicated by the white lamp S1.H1.
  • Page 11 To replace the filter, necessarily disconnect the device from the power supply system and re- fer the Fig. No.5. 26.06.2019 Filtering unit BIG-2000-N...
  • Page 12 Remember to empty the waste container. To do this, clasp off the lockings, slide the con- tainer out, and remove the foil bag with dust. Subsequently, put in a new foil bag, insert the container and close the clasp locks. CAUTION: Manufacturer does not deliver the foil waste bags. Filtering unit BIG-2000-N 26.06.2019...
  • Page 13: Troubleshooting Guide

    Every time, during the filter cleaning, examine the state of the filter fabric surface, and search for mechanical damages. Replacement way of the cartridge filter is described in Section 7 of the present Use and Maintenance Manual. 26.06.2019 Filtering unit BIG-2000-N...
  • Page 14: Occupational Health And Safety

    Start up and the operation use are only admissible after getting acquainted with the contents of the present manual. In the aspect of safety, BIG-2000-N will not cause hazard, when the instruc- tions in the present Use and Maintenance Manual and the general rules of Occupational Health and Safety are observed.
  • Page 15 Fig. No.6 – Compressed air tank 26.06.2019 Filtering unit BIG-2000-N...
  • Page 16 / markings must be wiped out, so the tank would never be returned to operation. Do not introduce any constructional changes / modifications on the compressed air tank, its application in contradiction with its purpose is forbidden. Filtering unit BIG-2000-N 26.06.2019...
  • Page 17: Sample Of The Declaration Of Conformity

    Declaration of Conformity EC No. …………….. Manufacturer (eventually the authorized representative / importer): name: KLIMAWENT S.A. address: 81-571 Gdynia, ul. Chwaszczyńska 194 A person, authorized for issuing the technical documentation: Teodor Świrbutowicz, KLIMAWENT S.A. hereby declares that the appliance: name: filtering unit...
  • Page 18 NOTES: Filtering unit BIG-2000-N 26.06.2019...
  • Page 19 NOTES: 26.06.2019 Filtering unit BIG-2000-N...
  • Page 20 Producer: KLIMAWENT S.A. 81-571 Gdynia, ul. Chwaszczyńska 194 tel. 058 629 64 80 fax 058 629 64 19 e-mail: klimawent@klimawent.com.pl www.klimawent.com.pl 804U12 BIG-2000-N 26.06.2019/EN Filtering unit BIG-2000-N 26.06.2019...

Table of Contents