Assembly and Start-up ................ 7 Operational Use .................. 9 Troubleshooting Guide ................ 13 Maintenance ..................13 Occupational Health and Safety ............14 Transport and Storage ................ 14 Terms of warranty ................14 Sample of the Declaration of Conformity ..........17 Filtering unit BIG-2000-N 26.06.2019...
The construction of the BIG-2000-N filtering unit meets the requirements of the current state of technology as well as the safety and health assurances included in: ...
2. Application BIG-2000-N filtering unit is appropriate for cleaning the air contaminated with dust- and gaseous impurities, arising during various manufacturing processes. It is perfect in removal of dry dust and fumes emitted during welding, gaseous metal cutting and during other processes, in chemical industry, food processing , pharmaceutics, plastic processing .
Carbon spunbond constitutes replaceable WFCR-BIG-2000 element of the filter. 5. Structure and Function BIG-2000-N filtering unit consists of: – steel sheet housing, – radial fan, – spark catcher, – cut-off dampers – to cut off the air flow while the fan is switched off, –...
Page 6
Additionally, the device is equipped with a spark catcher, to avoid entering the welding sparks being drawn into the extraction arm during the welding process. BIG-2000-N filtering unit is fitted with cut-off dampers closing the air inlets for the time when the fan is switched off. This enables additional final filter shaking (cleaning).
6. Assembly and Start-up The structure of BIG-2000-N filtering unit is adapted for attachment of ERGO LUX extraction arms of workrange 2, 3 or 4 metres and diameter 160 mm. Prior to the operational use, connect the device to the external compressed air installation of pressure 6 –...
Page 8
Fig. No.2 – Connection diagram – filtering unit BIG-2000-N Filtering unit BIG-2000-N 26.06.2019...
4. The device is equipped with a five-metres-long power supply cable with a plug. To connect the device to the power supply, simply insert the plug into the socket. 7. Operational Use Connection diagram of the appliance is illustrated in Fig. No.2. Fig. No.3 – Control unit BIG-2000-N – front cover 26.06.2019 Filtering unit BIG-2000-N...
Page 10
Fig. No.4 – Control unit BIG-2000-N – inside START-UP OF THE APPLIANCE: 1. Open the compressed air valve. 2. Insert the plug into the power supply socket. 3. Switch on the motor switch Q1M. 4. Switch on the power supply by setting the S1 into position “ON” ; this will be indicated by the white lamp S1.H1.
Page 11
To replace the filter, necessarily disconnect the device from the power supply system and re- fer the Fig. No.5. 26.06.2019 Filtering unit BIG-2000-N...
Page 12
Remember to empty the waste container. To do this, clasp off the lockings, slide the con- tainer out, and remove the foil bag with dust. Subsequently, put in a new foil bag, insert the container and close the clasp locks. CAUTION: Manufacturer does not deliver the foil waste bags. Filtering unit BIG-2000-N 26.06.2019...
Every time, during the filter cleaning, examine the state of the filter fabric surface, and search for mechanical damages. Replacement way of the cartridge filter is described in Section 7 of the present Use and Maintenance Manual. 26.06.2019 Filtering unit BIG-2000-N...
Start up and the operation use are only admissible after getting acquainted with the contents of the present manual. In the aspect of safety, BIG-2000-N will not cause hazard, when the instruc- tions in the present Use and Maintenance Manual and the general rules of Occupational Health and Safety are observed.
Page 15
Fig. No.6 – Compressed air tank 26.06.2019 Filtering unit BIG-2000-N...
Page 16
/ markings must be wiped out, so the tank would never be returned to operation. Do not introduce any constructional changes / modifications on the compressed air tank, its application in contradiction with its purpose is forbidden. Filtering unit BIG-2000-N 26.06.2019...