5 Maintenance

5.1 Maintenance Schedule

Interval
Daily
Bi-monthly
Annually

5.2 Maintenance Procedures

5.2.1 Lamp Replacement
1. Disconnect and lock out power to the beacon.
2. Remove the four ¼ - 20 bolts that mount the lamp to the rain cap.
3. Locate the electrical hub in the center of the rain cap.
4. Remove ½" conduit cover and gasket.
5. Remove the appropriate wire nuts.
6. Remove the cord strain relief from the electrical hub.
7. The lamp now is free to be removed.
8. Repeat above steps in reverse order to install replacement lamp.
5.2.2 Beam Angle Adjustment
All beacons are shipped from the factory preset at an elevation angle of 5
degrees, per FAA requirements.
To adjust the beacon beam to a different angle, perform the following procedure:
1. The beacon head has four screws that secure the lamp to the lamp support
brackets. Loosen these four screws. This will allow the head to pivot on
the top mounting bolts. (See figure 3)
2. Locate the beam elevation label on the right side of the beacon head. (See
figure 3)
3. Locate the sight window at the bottom of the right support bracket. (See
figure 3)
12
Task
Inspect for lamp failure and proper rotation.
Inspect cleanliness of glass. Clean as necessary.
Inspect all electrical connections.
Replace beacon lamps at 50,000 hours.