Kenwood TK-3217 Service Manual page 51

Uhf fm transceiver
Hide thumbs Also See for TK-3217:
Table of Contents

Advertisement

TK-3217
Receiver Section
Item
Condition
1.BPF Wave
(1)Center frequency
Adjust
Spectrum analyzer setting analyzer
Center-f : 460MHz
Span : 200MHz
RBW : 30kHz
VBW : 30kHz
ATT
(2)High-edge frequency
Spectrum analyzer setting
Center-f : 480MHz
(3)Low-edge frequency
Spectrum analyzer setting
Center-f : 440MHz
2.Sensitivity
TEST CH: Low
check
[Wide]
SSG otuput:–117 dBm(0.3µV) AF VTVM
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–115 dBm(0.4µV)
SSG MOD:1.5kHz
3.SQL1
TEST CH: Center
(Threshold)
writing
[Wide]
SSG otuput:–123 dBm(0.16µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–122 dBm(0.18µV)
SSG MOD:1.5kHz
4.SQL9
TEST CH: Center
(Tight)
writing
[Wide]
SSG otuput:–117 dBm(0.3µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH:Center
SSG otuput:–116 dBm(0.35µV)
SSG MOD:1.5kHz
5.BATT
BATT terminal voltage:5.75V DVM
Detection
Writing
50
ADJUSTMENT /
Measurement
Test equipment
Spectrum
: 5dB
SSG
Center
DVM
High
Oscilloscope
Low
High
Low
High
调整
Adjustment
Terminal
Parts
ANT
Programming
BPF
Software:
KPG-100D
ANT
Programming
Software:
KPG-100D
ANT
BATT terminal
Specifications/
Remark
Method
Adjust the
REF -20.0 dBm
10 dB/
A_Write Norm B_Blank Norm -60.05 dBm
CENTER
waveform as
460 MHz
shown to the
right.
CENTER 460 MHz
SPAN 200.0 MHz
RBW 30 kHz
VBW 30 kHz SWP 450 ms
REF -20.0 dBm
10 dB/
A_Write Norm B_Blank Norm -58.73 dBm
CENTER
480 MHz
CENTER 480 MHz
SPAN 200.0 MHz
RBW 30 kHz
VBW 30 kHz SWP 450 ms
REF -20.0 dBm
10 dB/
A_Write Norm B_Blank Norm -58.32 dBm
CENTER
440 MHz
CENTER 440 MHz
SPAN 200.0 MHz
RBW 30 kHz
VBW 30 kHz SWP 450 ms
Check
12dB SINAD or more
Write
Squelch open
Write
BATT terminal
voltage:5.75V
MKR 460 MHz
ATT 5 dB
MKR 480 MHz
ATT 5 dB
MKR 440 MHz
ATT 5 dB

Hide quick links:

Advertisement

Table of Contents
loading