AEG FEE63600PM User Manual page 22

Hide thumbs Also See for FEE63600PM:
Table of Contents

Advertisement

Available languages

Available languages

22
www.aeg.com
Problem and alarm code
The temperature of the wa‐
ter inside the appliance is
too high or malfunction of
the temperature sensor oc‐
curred.
The display shows i61 or
i69.
Technical malfunction of the
appliance.
The display shows iC0 or
iC3.
The level of water inside the
appliance is too high.
The display shows iF1.
The appliance stops and
starts more times during op‐
eration.
The programme lasts too
long.
The remaining time in the
display increases and skips
nearly to the end of the pro‐
gramme duration.
Small leak from the appli‐
ance door.
The appliance door is diffi‐
cult to close.
Rattling or knocking sounds
from the inside of the appli‐
ance.
The appliance trips the cir‐
cuit-beaker.
Possible cause and solution
Make sure that the temperature of the inlet water does
not exceed 60°C.
Switch the appliance off and on.
Switch the appliance off and on.
Switch the appliance off and on.
Make sure that the filters are clean.
Make sure that the outlet hose is installed at the right
height above the floor. Refer to the installation instruc‐
tions.
It is normal. It provides optimal cleaning results and en‐
ergy savings.
If the delay start option is set, cancel the delay setting or
wait for the end of the countdown.
Activate the TimeSaver option to reduce the programme
duration.
Activating options can increase the programme duration.
This is not a defect. The appliance is working correctly.
The appliance is not levelled. Loosen or tighten the ad‐
justable feet (if applicable).
The appliance door is not centred on the tub. Adjust the
rear foot (if applicable).
The appliance is not levelled. Loosen or tighten the ad‐
justable feet (if applicable).
Parts of the tableware are protruding from the baskets.
The tableware is not properly arranged in the baskets.
Refer to basket loading leaflet.
Make sure that the spray arms can rotate freely.
The amperage is insufficient to supply simultaneously all
the appliances in use. Check the socket amperage and
the capacity of the meter or turn off one of the applian‐
ces in use.
Internal electrical fault of the appliance. Contact an Au‐
thorised Service Centre.

Advertisement

Chapters

Table of Contents
loading

Table of Contents