The wiring diagram is located on the inside of the opposite side of the cover.
The cables used should have an outer diameter between 6 and 12 mm. In order to protect the housing
against water entering, the six screws of the housing must be tightened firmly. Further information can
be found in the chapter "Wiring diagram".
Functions
1
Restart box
2
State LED
3
Mains voltage display
4
Pump motor connection
Technical data
Input voltage (V)
Input frequency (㎐)
Amperage (A)
Max. pressure (bar)
Max. temperature (
Connections (㎜)
Protection class
Functional description of the general operating mode of the pump control
The pump control consists of a pressure switch and a water flow switch. The switching cycles are then
determined from the two switching states of the pressure switch and the water flow switch.
Water pressure switch actuated + water flow switch not actuated = normal switch-off
(delay of approx. 3–8 sec. until switch-off)
Water pressure switch not actuated + water flow switch actuated = pump on
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
220–250
50
10
10
)
60
32.89–33.25 (external threads)
IP 65
Item 50612, 51249
5
Pressure adjusting screw
6 and 8
1" / 25,4 mm screw connection
7
Power supply
9
Pressure indication
Page 4